Mohican Substation Clause Samples

The 'Mohican Substation' clause defines the specific responsibilities, rights, or conditions related to the Mohican Substation within the context of the agreement. This clause typically outlines aspects such as ownership, maintenance obligations, access rights, or operational requirements for the substation. For example, it may specify which party is responsible for upgrades or repairs, or set forth protocols for coordinating work at the site. The core function of this clause is to ensure clarity and prevent disputes by clearly delineating each party's roles and expectations regarding the Mohican Substation.
Mohican Substation. All modifications shall be completed in the Mohican Substation yard and control house.
Mohican Substation. All modifications at the Mohican Substation will be completed in its yard and control enclosure. It is assumed that all existing wiring trays and panels have sufficient capacity to accommodate the changes. 6-1 SERVICE AGREEMENT NO. 2556
Mohican Substation. All modifications shall be completed in the Mohican Substation yard and control house. The Connecting Transmission Owner’s Mohican rebuild firm project underway is expected to be complete prior to the In-Service Date for the Small Generating Facility. The SUFs identified in this section, assume that the rebuild has been completed. At the time the facilities study was performed, there is adequate space in the control enclosure to accommodate the additional facilities required for to accommodate the interconnection of the Small Generating Facility.
Mohican Substation. All modifications shall be completed in the Mohican Substation yard and control house. a) Line 15 Protection Packages 6-1 SERVICE AGREEMENT NO. 2720 The existing Line 15 protection is a POTT for the ‘A’ package and step distance for the ‘B’ package. The existing A package relay is a SEL-321 and will be reused and reset to accommodate the generation. However, the existing B package relay is a SEL-221 which cannot be reset to accommodate the generation and will be replaced with an ERLPhase LPro. DTT transmit and receive to the ▇▇▇▇▇ Solar Collector Station will be added. DTT will be sent to the ▇▇▇▇▇ Solar Collector Station for a line relay operation and R15 breaker failure. DTT for breaker failure will be received from the ▇▇▇▇▇ Solar Collector Station. The ‘A’ package line relay will be used for DTT receive supervision and will be used to trip and drive reclosing to lockout. The existing electromechanical reclosing relays shall be replaced with one (1) SEL351 6 relay to allow addition of drive to lockout (“DTL”) for DTT receive. A GARD8000 will be added for DTT to and from the ▇▇▇▇▇ Solar Collector Station.
Mohican Substation. All modifications shall be completed in the Mohican Substation yard and control house. The Connecting Transmission Owner’s Mohican rebuild firm project underway is expected to be complete prior to the In-Service Date for the Small Generating Facility. The SUFs identified in this section, assume that the rebuild has been completed. At the time the facilities study was performed, there is adequate space in the control enclosure to accommodate the additional facilities required for to accommodate the interconnection of the Small Generating Facility. a) Protection The existing Line 15 ‘A’ package is a permissive overreaching transfer trip (“POTT”) scheme using an ABB RED670 relay and the ‘B’ package is step distance using a GE-L90 relay. Both ‘A’ and ‘B’ packages will be reused and reset to accommodate the Small Generating Facility. DTT transmit and receive will be added to the ▇▇▇▇▇▇ Solar Collector Substation, which will require the addition of one (1) RFL GARDPro (or Connecting Transmission Owner approved equivalent). DTT will be sent to the ▇▇▇▇▇▇ Solar Collector Substation for a line relay operation or R15 breaker failure and DTT for breaker failure will be received from the ▇▇▇▇▇▇ Solar Collector Substation.

Related to Mohican Substation

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Underground Facilities All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any encasements containing such facilities, including without limitation those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems.

  • Pipelines Developer shall have no interest in the pipeline gathering system, which gathering system shall remain the sole property of Operator or its Affiliates and shall be maintained at their sole cost and expense.

  • Interconnection 2.1 This section applies to linking with suppliers providing public telecommunications transport networks or services in order to allow the users of one supplier to communicate with users of another supplier and to access services provided by another supplier, where specific commitments are undertaken.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If WCS chooses to subtend a Verizon access Tandem, WCS’s NPA/NXX must be assigned by WCS to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 WCS shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from WCS’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office WCS utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow WCS’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.