Project Site Security Sample Clauses

The Project Site Security clause establishes the responsibilities and requirements for maintaining safety and security at the location where a project is being carried out. Typically, this clause outlines which party is responsible for securing the site, such as installing fencing, controlling access, and monitoring for unauthorized entry or theft. It may also specify procedures for reporting incidents and the use of security personnel or surveillance systems. The core function of this clause is to protect the project site, personnel, and materials from loss, damage, or harm, thereby minimizing risks and ensuring a safe working environment.
POPULAR SAMPLE Copied 1 times
Project Site Security. The Concessionaire shall be responsible at its cost, for procurement, transport, receiving, unloading and safe keeping of all plant and machinery, materials, Concessionaire's Equipment and other things required for the completion of the Works, services and ‘Operation & Maintenance of Food Court’ and ‘Upkeeping & Maintenance of Library’Unless otherwise stated in this Concession Agreement: i) The Concessionaire shall be responsible for keeping unauthorized persons off the Project Site and prevent encroachment on the Project Site during the Construction Period of the temporary structure. ii) Authorized persons during the Construction Period shall be limited to the employees of the Concessionaire, employees of its Sub-contractors and employees and persons authorized by the Authority.
Project Site Security. The Concessionaire shall be responsible at its cost, for procurement, transport, receiving, unloading and safe keeping of all plant and machinery, materials, Concessionaire's Equipment and other things required for the completion of the Works, services and operation and maintenance of the Hotel Unless otherwise stated in this Concession Agreement: i The Concessionaire shall be responsible for keeping unauthorized persons off the Project Site and prevent encroachment on the Project Site during the Development Period.
Project Site Security. All access doors to the Project and electrical equipment shall be locked, fenced, or both, as appropriate, to prevent entry by non­ authorzed persons. Entrances to restricted areas shall be gated and locked during non-working hours. If the Owner identifies problems with unauthorized access, the Owner shall work to implement additional security measures.
Project Site Security. The Concessionaire shall be responsible at its cost, for procurement, transport, receiving, unloading and safe keeping of all Plant and Machinery, Materials, Concessionaire's Equipment and other things required for the completion of the Works, services and operation and maintenance of the Ecotourism & Adventure Park. Unless otherwise stated in this Concession Agreement: i) The Concessionaire shall be responsible for keeping unauthorized persons off the Project Site and prevent encroachment on the Project Site during the Construction Period. ii) Authorized persons during the Construction Period shall be limited to the employees of the Concessionaire, employees of its Subcontractors and employees and persons authorized by the Concessioning Authority.
Project Site Security. 4.1. Wind Turbines exteriors shall not be climbable up to fifteen (15) feet above ground surface. 4.2. All access doors to Wind Turbines and electrical equipment shall be locked, fenced, or both, as appropriate, to prevent entry by non-authorized persons. 4.3. Entrances to the Project Site shall be gated, and locked during non-working hours. If problems with unauthorized access are identified, the Project shall work to implement additional security measures.
Project Site Security. During the performance of any of the Repair and Retrofit Activities at the Project site, the Project Company shall provide all necessary and reasonably appropriate safeguards for the protection of the Project, and all persons and other property related thereto, including lights and barriers, guard service, controlled access, and other measures reasonably required to prevent vandalism, theft, and danger to the Project and personnel. The Project Company shall keep Owner informed of any security breaches promptly upon the occurrence thereof.
Project Site Security. Integrator shall provide appropriate security for each Project Site, and shall take all reasonable precautions and provide protection to prevent damage, injury, or loss to the Work and materials and equipment to be incorporated therein, as well as all other property at or on each Project Site, whether owned by Integrator, TxDOT, or any other Person.
Project Site Security. Contractor shall follow and access the Project Site in accordance with the security procedures set forth in the HSE Rules starting on the Services Commencement Date. If Contractor becomes aware that representatives of any Governmental Authority visit the Project Site for any purpose related to the Work, Contractor shall immediately notify Owner. .
Project Site Security. During the performance of any of the Work at the Project Site, Contractor shall provide all necessary and reasonably appropriate safeguards at the Project Site at which Contractor conducts the Work or any part thereof, for the protection of the Work, the Project, and all persons and other property related thereto, including lights and barriers, guard service, controlled access, and other measures reasonably required to prevent vandalism, theft, and danger to the Project and personnel. Notwithstanding the foregoing, Contractor acknowledges that Owner and the other Persons operating at the Project Site have implemented their own security measures, and Contractor shall cooperate with and follow all such security measures to the extent Contractor has been provided copies of such security programs or measures. Within thirty (30) days after the Full Notice to Proceed Date, Contractor shall provide a draft security assurance program to Owner for Owner’s review and approval. Owner shall promptly review and provide any comments on such draft program to Contractor. If Owner provides any comments with respect to such security assurance program to Contractor, Contractor shall incorporate changes into the security assurance program addressing such comments, and resubmit the security assurance program to Owner. If Owner fails to comment within twenty (20) days after receipt of such draft, Owner shall be deemed to have accepted such security assurance program. Contractor shall follow the approved security assurance program during the performance of the Work.

Related to Project Site Security

  • Site Security While providing services at a DSHS location, the Contractor, its agents, employees, or Subcontractors shall conform in all respects with physical, fire, or other security regulations specific to the DSHS location.

  • Project Site The “Project Site” is the place where the Work is being carried on.

  • Connecting Transmission Owner’s Attachment Facilities Construction The Connecting Transmission Owner’s Attachment Facilities shall be designed and constructed in accordance with Good Utility Practice. Upon request, within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Connecting Transmission Owner and Developer agree on another mutually acceptable deadline, the Connecting Transmission Owner shall deliver to the Developer “as-built” drawings, relay diagrams, information and documents for the Connecting Transmission Owner’s Attachment Facilities set forth in Appendix A. The Connecting Transmission Owner shall not transfer operational control of the Connecting Transmission Owner’s Attachment Facilities and Stand Alone System Upgrade Facilities to the NYISO upon completion of such facilities.

  • The Site The site of the Project Highway (the “Site”) shall comprise the site described in Schedule-A in respect of which the Right of Way shall be provided by the Authority to the Contractor. The Authority shall be responsible for: (a) acquiring and providing Right of Way on the Site in accordance with the alignment finalised by the Authority, free from all encroachments and encumbrances, and free access thereto for the execution of this Agreement; and (b) obtaining licences and permits for environment clearance for the Project Highway.

  • Student Data Property of LEA All Student Data transmitted to the Provider pursuant to the Service Agreement is and will continue to be the property of and under the control of the LEA. The Provider further acknowledges and agrees that all copies of such Student Data transmitted to the Provider, including any modifications or additions or any portion thereof from any source, are subject to the provisions of this DPA in the same manner as the original Student Data. The Parties agree that as between them, all rights, including all intellectual property rights in and to Student Data contemplated per the Service Agreement, shall remain the exclusive property of the LEA. For the purposes of FERPA, the Provider shall be considered a School Official, under the control and direction of the LEA as it pertains to the use of Student Data, notwithstanding the above.