Remedy Selection Decision Factors. 6.2.1 Short- and Long-Term Effectiveness Each corrective measure alternative must be evaluated as to its effectiveness in protecting human health and the environment and meeting the corrective action objectives. Both short- and long-term components of effectiveness must be evaluated; short-term referring to the construction and implementation period, and long-term referring to the period after the remedial action is complete. Estimate approximately how much time it will take to implement each corrective measure alternative, how much time to see initial beneficial results, and how much time to achieve the corrective action objectives. The evaluation of short-term effectiveness must include possible threats to the safety of nearby communities, workers, and environmentally sensitive areas (e.g., oceans, wetlands) during construction of the corrective measure alternative. Factors to consider are fire, explosion, exposure to hazardous substances and potential threats associated with treatment, excavation, transportation and re-disposal or containment of waste material. The evaluation of long-term effectiveness must include possible threats to the safety of nearby communities workers, and environmentally sensitive areas (e.g., oceans, wetlands) during operation of the corrective measure alternative.
Remedy Selection Decision Factors 

Related to Remedy Selection Decision Factors

  • SITE-BASED DECISION MAKING A. The District shall provide the training and staff development to support accountability/site- based decision-making activities. Teachers shall be given release time to attend these programs. B. Participation on the SAC shall not serve as a basis for the evaluation of any teacher. C. A minimum of three (3) to a maximum of five (5) teachers from each school shall serve on their school’s budget advisory committee formed for the purpose of making recommendations on the school’s general fund budget. Teacher members shall be elected by the faculty. Minutes from such meetings may be requested by the faculty and may be posted on the CTA bulletin board at the school by the Association Representative.

  • Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.

  • Power Factor Design Criteria Developer shall design the Large Generating Facility to maintain an effective power delivery at demonstrated maximum net capability at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all generators in the New York Control Area on a comparable basis. The Developer shall design and maintain the plant auxiliary systems to operate safely throughout the entire real and reactive power design range. The Connecting Transmission Owner shall not unreasonably restrict or condition the reactive power production or absorption of the Large Generating Facility in accordance with Good Utility Practice.

  • Desirable Selection Criteria Post registration qualification in the area of specialty or evidence of significant progression towards one.

  • Retainage for Unacceptable Corrective Action Plan or Plan Failure If the corrective action plan is unacceptable to the Department or Customer, or implementation of the plan fails to remedy the performance deficiencies, the Department or Customer will retain ten percent (10%) of the total invoice amount. The retainage will be withheld until the Contractor resolves the performance deficiencies. If the performance deficiencies are resolved, the Contractor may invoice the Department or Customer for the retained amount. If the Contractor fails to resolve the performance deficiencies, the retained amount will be forfeited to compensate the Department or Customer for the performance deficiencies.