Information Systems Acquisition Development and Maintenance a. Client Data – Client Data will only be used by State Street for the purposes specified in this Agreement.
Synchronization, Commissioning and Commercial Operation 5.1.1 The SPG shall give PGVCL at least thirty (30) days’ advanced preliminary written notice and at least fifteen (15) days’ advanced final written notice, of the date on which it intends to synchronize the Solar Power Project to the Grid System. 5.1.2 Subject to Article 5.1.1, the Power Project may be synchronized by the SPG to the Grid System when it meets all the connection conditions prescribed in applicable Grid Code then in effect and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 5.1.3 The synchronization equipment and all necessary arrangements / equipment including RTU for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the SPG at its generation facility of the Power Project at its own cost. The SPG shall synchronize its system with the Grid System only after the approval of synchronization scheme is granted by the head of the concerned substation/ and checking/verification is made by the concerned authorities of the PGVCL. 5.1.4 The SPG shall immediately after each synchronization/tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. In addition, the SPG will inject in-firm power to grid from time to time to carry out operational/ functional test prior to commercial operation. For avoidance of doubt, it is clarified that Synchronization / Connectivity of the Project with the grid shall not to be considered as Commissioning of the Project. 5.1.5 The SPG shall commission the Project within nine (9) Months from the Date of execution of this PPA. Declaration of COD shall be certified by the commissioning committee. 5.1.6 The Parties agree that for the purpose of commencement of the supply of electricity by SPG to PGVCL, liquidated damages for delay etc., the Scheduled Commissioning Date as defined in this Agreement shall be the relevant date.
Screening and Assessment Grantee shall: 1. Comply with all applicable rules in the TAC for SUD programs as stated in the SUD UM Guidelines Information, Rules, and Regulations regarding Screening and Assessment. 2. When documenting a CMBHS Substance Use Disorder screening, Grantee shall conduct the screening in a confidential, face-to-face interview unless there is documented justification for an interview by phone. 3. Document Financial Eligibility in CMBHS as required in the SUD UM Guidelines. 4. Conduct and document a CMBHS SUD Initial Assessment with the client to determine the appropriate levels of care for SUD treatment. The CMBHS assessment will identify the impact of substances on the physical, mental health, and other identified issues including Tuberculosis, Hepatitis C, sexually transmitted infection (STI), and Human Immunodeficiency Virus (HIV). i. If client indicates risk for these communicable diseases, Grantee shall refer the client to the appropriate community resources for further testing and counseling. ii. If the client is at risk for HIV, Grantee shall refer the client to pre and post- test counseling on HIV. 5. Grantee will also consider referring to the TRA Statewide HIV Intensive Residential Treatment facility to concurrently address medical needs and SUD. 6. If a client is living with HIV, Grantee will refer the client to the appropriate community resources to complete the necessary referrals and health related paperwork. 7. The assessment shall be signed by a Qualified Credential Counselor (QCC) and filed in the client record within three (3) service days of admission or a program may accept an evaluation from an outside entity if it meets the criteria for admission and was completed during the thirty (30) business days preceding admission.
Testing and Acceptance Within […***…] after RFM’s delivery of the IC Design File to ST, ST shall manufacture and deliver a commercially reasonable quantity of evaluation Product to RFM for evaluation testing. Upon RFM’s receipt of such Products from ST, RFM shall test such Products with the applicable Evaluation Software and in the applicable Evaluation Circuit Design to determine if the IC Design for such Products conforms to the applicable Specifications. Upon completion of such testing, RFM shall provide ST with the data from such testing (“Evaluation Data”). Upon ST’s receipt of the Evaluation Data, ST shall evaluate whether the Evaluation Data indicates that the IC Design conforms to the Specifications in all material respects. ST shall accept or reject the IC Design based on the Evaluation Data and shall give RFM written notice thereof within seven (7) calendar days after RFM’s delivery of the Evaluation Data to ST. An IC Design will be deemed accepted by ST if RFM has not received notification of rejection of such IC Design from ST within seven (7) calendar days after RFM’s delivery of the applicable Evaluation Data to ST. ST’s refusal to accept the IC Design must be reasonable, must be in writing and must be accompanied by a reasonably detailed description of the manner in which the IC Design fails to comply with the Specifications in all material respects (collectively, the “Deficiencies”) so that RFM can have the opportunity to correct the Deficiencies. If ST properly rejects the IC Design, RFM shall use commercially reasonable efforts to correct any Deficiencies and redeliver a corrected IC Design File within […***…] after RFM’s receipt of the rejection notice and the foregoing provisions set forth in this Section 3.3 shall be reapplied until the IC Design is accepted; provided, however, that upon the […***…] or any subsequent rejection, either party may terminate this Agreement upon thirty (30) calendar days prior written notice to the other party, unless the IC Design is accepted during such notice period.
JOB FAMILY: APPLICATIONS DEVELOPMENT Job Title: Enterprise Application Integration (EAI) Engineer Job#: 1230 General Characteristics