The "Sampling system" clause defines the procedures and requirements for collecting and analyzing samples to ensure product quality or compliance. Typically, this clause outlines the methods for selecting samples, the frequency of sampling, and the standards or criteria that must be met during testing. By establishing a clear framework for sampling, the clause helps ensure consistent quality control and provides a basis for resolving disputes over product conformity or performance.
Sampling system. The provisions of Appendix 2 and Appendix 3 to Annex 4a to the 07 series of amendments to this Regulation apply.
Sampling system. EPC - Exhibit B TENASKA GEORGIA GENERATION PROJECT --------------- Page 83 of 132 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- This section covers the engineering, design, manufacture and installation of a sampling system of local grab samples for the project. The sampling system will extract samples from selected points to enable a chemist to perform specific analysis. Manual grab sample points shall be provided on demineralized water, waste drains, fuel oil and raw water. -------------------------------------------------------------------------------- EPC - Exhibit B TENASKA GEORGIA GENERATION PROJECT --------------- Page 84 of 132 -------------------------------------------------------------------------------- --------------------------------------------------------------------------------
Sampling system. The sample gas from the well head is mostly steam that is under high pressure (~15 bar) and high temperature (~200°C). As this cannot be used directly for measurement it must be conditioned by condensing the steam and separating the resulting water to provide a dry gas sample for measurement. It may also be scrubbed for H2S using a filter that precipitates the H2S, such as CuSO4 solution or granules of carbon or copper. However, the use of copper was found to be ineffective prior to the trial and the use of both CuSO4 solution and carbon granules were found to be ineffective during the trial. The sample gas is accessed from a test point on the pipeline just outside the igloo using a small steam separator and regulator as shown in Figure 5. This then passes through two cooling coils that are immersed into buckets, one containing free flowing water from a nearby water well that is naturally heated to ~25°C. A large amount of water is needed due to the large amount of heat in the steam flow. As this is slightly warmer than the expected temperatures inside the igloo there is a risk of condensation in the sampling system tubing, so a second bucket was filled with snow to reduce the sample gas temperature further.
Sampling system. Two (2) sample panels shall be provided. One per power block.

Related to Sampling system

  • Calibration The comparison of a measurement system or device of unverified accuracy with a measurement system of known and greater accuracy to detect deviation of the unverified measurement system from required performance specifications (of the unverified measurement system or device) and to quantify all measured values to applicable units of the international system of units.

  • Sampling The Licensee agrees that the Composition is purchased as a “Work Made for Hire” whereby the clearing of any sampled materials is the responsibility of Licensee.

  • Monitoring System In each case in which the Custodian has exercised delegated authority to place Assets with a Foreign Custodian, the Custodian shall establish a system, to re-assess or re-evaluate selected Foreign Custodians, at least annually in accordance with Rule 17f-5(c)(3).

  • System Logging The system must maintain an automated audit trail which can 20 identify the user or system process which initiates a request for PHI COUNTY discloses to 21 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY, 22 or which alters such PHI. The audit trail must be date and time stamped, must log both successful and 23 failed accesses, must be read only, and must be restricted to authorized users. If such PHI is stored in a 24 database, database logging functionality must be enabled. Audit trail data must be archived for at least 3 25 years after occurrence.

  • Evaluation Software If the Software is an evaluation version or is provided to You for evaluation purposes, then, unless otherwise approved in writing by an authorized representative of Licensor, Your license to use the Software is limited solely for internal evaluation purposes in non-production use and in accordance with the terms of the evaluation offering under which You received the Software, and expires 90 days from installation (or such other period as may be indicated within the Software). Upon expiration of the evaluation period, You must discontinue use of the Software, return to an original state any actions performed by the Software, and delete the Software entirely from Your system and You may not download the Software again unless approved in writing by an authorized representative of Licensor. The Software may contain an automatic disabling mechanism that prevents its use after a certain period of time. RESTRICTIONS