Time Synchronization Clause Samples

The Time Synchronization clause establishes requirements for aligning the time settings of systems or devices involved in an agreement or technical environment. Typically, it mandates that all relevant equipment use a common time source, such as a network time protocol (NTP) server, to ensure that logs, transactions, and records are accurately timestamped and consistent across platforms. This clause is essential for maintaining data integrity, facilitating troubleshooting, and supporting compliance or audit processes by ensuring that all time-dependent activities are properly coordinated.
Time Synchronization. It is very challenging to synchronize the clocks between the video and the single- loop data sequences because of uncertainties with the data collection, compression, and transmission processes. The video signal from a WSDOT surveillance camera is transmitted to a control cabinet via coaxial cable and then sent to a communications hub via fiber optic cable. At the communications hub, it is combined with video signals from many other cameras through the Frequency Division Multiplexing (FDM) technique. The combined video signals are then transmitted to the WSDOT TSMC in Shoreline via glass fiber. At the TSMC, the received video signals are de-multiplexed and connected
Time Synchronization. The System will support synchronization to a master clock source(s) using Network Time Protocol (NTP) V3 as defined by IETF ▇▇▇ ▇▇▇▇. The Contractor shall provide a network master clock source for the System and any ports necessary to connect the master clock source to PSAP CAD systems.
Time Synchronization. The system clock accuracy also affects the accuracy of the resulting metrics. It is essential for IP SLA operations like one-way latency (delay) to have precise time synchronization. Some of the other operations, also round-trip and interarrival time, are less sensitive to clock variations.
Time Synchronization. Time synchronisation is only to be done if required by the Employer: 1. Where a time synchronization source signal is required, it shall be provided by the Employer at EOD. The cabling will be provided and installed by the Contractor 2. The Contractor shall ensure that all other equipment forming part of the Lift Control System and LMS are synchronized to the station GPS. 3. Time-stamping of all alarms and events shall occur at the source.
Time Synchronization. All agencies are to make efforts to keep their time referencing devices synchronized. Updates should occur once per week via the National Research Council in Ottawa at (▇▇▇) ▇▇▇-▇▇▇▇ or via NRC web site or via Kingston CACC.

Related to Time Synchronization

  • Synchronization The Licensor hereby grants limited synchronization rights for One (1) music video streamed online (Youtube, Vimeo, etc..) for up to 500,000 non-monetized video streams on all total sites. A separate synchronisation license will need to be purchased for distribution of video to Television, Film or Video game.

  • Start-Up and Synchronization Consistent with the mutually acceptable procedures of the Developer and Connecting Transmission Owner, the Developer is responsible for the proper synchronization of the Large Generating Facility to the New York State Transmission System in accordance with NYISO and Connecting Transmission Owner procedures and requirements.

  • Synchronization, Commissioning and Commercial Operation 5.1.1 The SPG shall give PGVCL at least thirty (30) days’ advanced preliminary written notice and at least fifteen (15) days’ advanced final written notice, of the date on which it intends to synchronize the Solar Power Project to the Grid System. 5.1.2 Subject to Article 5.1.1, the Power Project may be synchronized by the SPG to the Grid System when it meets all the connection conditions prescribed in applicable Grid Code then in effect and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 5.1.3 The synchronization equipment and all necessary arrangements / equipment including RTU for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the SPG at its generation facility of the Power Project at its own cost. The SPG shall synchronize its system with the Grid System only after the approval of synchronization scheme is granted by the head of the concerned substation/ and checking/verification is made by the concerned authorities of the PGVCL. 5.1.4 The SPG shall immediately after each synchronization/tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. In addition, the SPG will inject in-firm power to grid from time to time to carry out operational/ functional test prior to commercial operation. For avoidance of doubt, it is clarified that Synchronization / Connectivity of the Project with the grid shall not to be considered as Commissioning of the Project. 5.1.5 The SPG shall commission the Project within nine (9) Months from the Date of execution of this PPA. Declaration of COD shall be certified by the commissioning committee. 5.1.6 The Parties agree that for the purpose of commencement of the supply of electricity by SPG to PGVCL, liquidated damages for delay etc., the Scheduled Commissioning Date as defined in this Agreement shall be the relevant date.

  • Scope of Interconnection Service 1.3.1 The NYISO will provide Energy Resource Interconnection Service and Capacity Resource Interconnection Service to Interconnection Customer at the Point of Interconnection. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver the Interconnection Customer’s power. The purchase or delivery of power and other services that the Interconnection Customer may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s or Connecting Transmission Owner’s tariffs. The Interconnection Customer will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the ISO OATT and Connecting Transmission Owner’s tariff. The execution of this Agreement does not constitute a request for, nor agreement to, provide Energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff or any Connecting Transmission Owner’s tariff. If Interconnection Customer wishes to supply or purchase Energy, Installed Capacity or Ancillary Services, then Interconnection Customer will make application to do so in accordance with the NYISO Services Tariff or Connecting Transmission Owner’s tariff.

  • Commissioning Commissioning tests of the Interconnection Customer’s installed equipment shall be performed pursuant to applicable codes and standards. The ISO and Connecting Transmission Owner must be given at least five Business Days written notice, or as otherwise mutually agreed to by the Parties, of the tests and may be present to witness the commissioning tests.