Use of Name and Reports Without the Advisor’s prior written consent, neither the Company nor any of its affiliates (nor any director, officer, manager, partner, member, employee or agent thereof) shall quote or refer to (i) the Advisor’s name or (ii) any advice rendered by the Advisor to the Company or any communication from the Advisor in connection with performance of their services hereunder, except as required by applicable federal or state law, regulation or securities exchange rule.
Access to NID 2.7.3.1 NewPhone may access the customer’s premises wiring by any of the following means and NewPhone shall not disturb the existing form of electrical protection and shall maintain the physical integrity of the NID: 2.7.3.1.1 BellSouth shall allow NewPhone to connect its Loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premises; 2.7.3.1.2 Where an adequate length of the customer’s premises wiring is present and environmental conditions permit, either Party may remove the customer premises wiring from the other Party’s NID and connect such wiring to that Party’s own NID; 2.7.3.1.3 Either Party may enter the subscriber access chamber or dual chamber NID enclosures for the purpose of extending a cross-connect or spliced jumper wire from the customer premises wiring through a suitable “punch-out” hole of such NID enclosures; or 2.7.3.1.4 NewPhone may request BellSouth to make other rearrangements to the customer premises wiring terminations or terminal enclosure on a time and materials cost basis. 2.7.3.2 In no case shall either Party remove or disconnect the other Party’s loop facilities from either Party’s NIDs, enclosures, or protectors unless the applicable Commission has expressly permitted the same and the disconnecting Party provides prior notice to the other Party. In such cases, it shall be the responsibility of the Party disconnecting loop facilities to leave undisturbed the existing form of electrical protection and to maintain the physical integrity of the NID. It will be NewPhone’s responsibility to ensure there is no safety hazard, and NewPhone will hold BellSouth harmless for any liability associated with the removal of the BellSouth Loop from the BellSouth NID. Furthermore, it shall be the responsibility of the disconnecting Party, once the other Party’s loop has been disconnected from the NID, to reconnect the disconnected loop to a nationally recognized testing laboratory listed station protector, which has been grounded as per Article 800 of the National Electrical Code. If no spare station protector exists in the NID, the disconnected loop must be appropriately cleared, capped and stored. 2.7.3.3 NewPhone shall not remove or disconnect ground wires from BellSouth’s NIDs, enclosures, or protectors. 2.7.3.4 NewPhone shall not remove or disconnect NID modules, protectors, or terminals from BellSouth’s NID enclosures. 2.7.3.5 Due to the wide variety of NID enclosures and outside plant environments, BellSouth will work with NewPhone to develop specific procedures to establish the most effective means of implementing this section if the procedures set forth herein do not apply to the NID in question.
Access to Personal Information by Subcontractors Supplier agrees to require any subcontractors or agents to which it discloses Personal Information under this Agreement or under any SOW to provide reasonable assurance, evidenced by written contract, that they will comply with the same or substantially similar confidentiality, privacy and security obligations with respect to such Personal Information as apply to Supplier under this Agreement or any SOW. Supplier shall confirm in writing to DXC that such contract is in place as a condition to DXC’s approval of use of a subcontractor in connection with any SOW. Upon request of DXC, Supplier will provide to DXC a copy of the subcontract or an extract of the relevant clauses. Supplier shall ensure that any failure on the part of any subcontractor or agent to comply with the Supplier obligations under this Agreement or any SOW shall be grounds to promptly terminate such subcontractor or agent. If during the term of this Agreement or any SOW, DXC determines, in its exclusive discretion, that any Supplier subcontractor or agent cannot comply with the Supplier obligations under this Agreement or with any SOW, then DXC may terminate this Agreement in whole or in part (with respect to any SOW for which such subcontractor or agent is providing services), if not cured by Supplier within the time prescribed in the notice of such deficiency.
Access to Site 3.05.1 Contractor may enter and leave the premises at all reasonable times without charge. Contractor and its employees may use the common areas and roadways of the premises where it is to perform the services together with all facilities, equipment, improvements, and services provided in connection with the premises for common use. This excludes parking for Contractor’s personnel. Contractor shall repair any damage caused by it or its employees as a result of its use of the common areas.
Authorization and Application of Overtime An employee who is required to work overtime shall be entitled to overtime compensation when the overtime worked is authorized in advance.