Backup and Disaster Recovery Management Sample Clauses

The Backup and Disaster Recovery Management clause outlines the responsibilities and procedures for safeguarding data and ensuring business continuity in the event of system failures or disasters. It typically requires regular data backups, secure storage of backup copies, and the development of a disaster recovery plan that details how services will be restored after an incident. This clause is essential for minimizing data loss, reducing downtime, and ensuring that critical operations can resume quickly following unexpected disruptions.
Backup and Disaster Recovery Management. Sensus will: (a) Perform daily backups of data providing one (1) year of history for auditing and restoration purposes. (b) Back-up and store data (on tapes or other storage media as appropriate) off-site to provide protection against disasters and to meet file recovery needs. (c) Conduct incremental and full back-ups to capture data, and changes to data, on the Application(s). (d) Replicate the Application(s) environments to a geographically separated data center location to provide a full disaster recovery environment for the Application production system. (e) Provide disaster recovery environment and perform fail-over to Disaster Recovery environment within forty-eight (48) hours of declared event. (f) Generate a report following each and any disaster measuring performance against the disaster recovery plan and identification of problem areas and plans for resolution. (g) Maintain a disaster recovery plan. In the event of a disaster, Sensus shall provide the services in accordance with the disaster recovery plan. (h) In the case of a disaster and loss of access to or use of the Application, Sensus would use commercially reasonable efforts per the Recovery Time Objectives (RTO) and Recovery Point Objectives (RPO) specified herein to restore operations at the same location or at a backup location within forty-eight (48) hours. (i) The Application shall have a RTO of forty-eight (48) hours. (j) The RPO shall be a full recovery of the Application(s), with an RPO of one (1) hours, using no more than a twenty-four (24) hour old backup. All meter-related data shall be pushed from each Base Station/TGB restoring the database to real-time minus external interfaced systems from the day prior. (k) Data from external interfaced systems shall be recreated within a forty-eight (48) hour period with the assistance of Customer personnel and staff, as needed.

Related to Backup and Disaster Recovery Management

  • Business Continuity and Disaster Recovery Bank shall maintain and update from time to time business continuation and disaster recovery procedures with respect to its global custody business, which are designed, in the event of a significant business disruption affecting Bank, to be sufficient to enable Bank to resume and continue to perform its duties and obligations under this Agreement without undue delay or disruption. Bank shall test the operability of such procedures at least annually. Bank shall enter into and shall maintain in effect at all times during the term of this Agreement reasonable provision for (i) periodic back-up of the computer files and data with respect to Customer and (ii) use of alternative electronic data processing equipment to provide services under this Agreement. Upon reasonable request, Bank shall discuss with Customer any business continuation and disaster recovery procedures of Bank. Bank represents that its business continuation and disaster recovery procedures are appropriate for its business as a global custodian to investment companies registered under the 1940 Act.

  • Disaster Recovery PFPC shall enter into and shall maintain in effect with appropriate parties one or more agreements making reasonable provisions for emergency use of electronic data processing equipment to the extent appropriate equipment is available. In the event of equipment failures, PFPC shall, at no additional expense to the Fund, take reasonable steps to minimize service interruptions. PFPC shall have no liability with respect to the loss of data or service interruptions caused by equipment failure, provided such loss or interruption is not caused by PFPC's own willful misfeasance, bad faith, gross negligence or reckless disregard of its duties or obligations under this Agreement.

  • Disaster Recovery Plan Contractor agrees that upon request of System Agency, Contractor shall provide copies of its most recent business continuity and disaster recovery plans.