CLIMATIC CONDITIONS Clause Samples
POPULAR SAMPLE Copied 1 times
CLIMATIC CONDITIONS. The transmitter covered by this specification must maintain the performance specified in this document, when operated continuously and at full power, in any worst natural combination of the following climatic conditions: -
13.1.1. Altitude At any altitude up to 2800m above mean sea level.
CLIMATIC CONDITIONS. For testing performed outdoors, the ambient temperature shall be between 5 °C and 32 °C. The indoors testing shall be performed at a temperature between 20 °C and 30 °C.
CLIMATIC CONDITIONS. The tenderers must acquaint themselves about the climatic conditions and changes in the same during the year. This aspect must be kept in mind while carrying out the designing. The Authority shall in no way be responsible on this account.
CLIMATIC CONDITIONS. The employed NTA are appropriate for operation in a surrounding climate according to ETS 300 019-1-3 [3] environment class 3.1 DIN IEC 721 [8].
CLIMATIC CONDITIONS. The Contractor shall suspend activity on and protect any portion of the Work that may be subject to damage by climatic or weather conditions.
CLIMATIC CONDITIONS. With regard to TN-4XE -------------------------------------------------------------------------------------------------------------------------- 305. Stationary Use Conditions acc. to prETS 300 019-2-3 Class T 3.2 NC NC NC 10.10305 -------------------------------------------------------------------------------------------------------------------------- 10.2 ELECTROMAGNETIC COMPATIBILITY 306. Compliance with EN 55022 class B C C C -------------------------------------------------------------------------------------------------------------------------- 307. Compliance with EN 50082 C C C -------------------------------------------------------------------------------------------------------------------------- 10.3 SAFETY REQUIREMENTS -------------------------------------------------------------------------------------------------------------------------- 308. Compliance with EN 60950 C C C -------------------------------------------------------------------------------------------------------------------------- 309. Compliance with IEC 825-1 and IEC 825-2 C C C -------------------------------------------------------------------------------------------------------------------------- 11 PHYSICAL CONSTRUCTION -------------------------------------------------------------------------------------------------------------------------- 310. Rack size according to ETSI 300 119, 600 mm x 300 mm C C C -------------------------------------------------------------------------------------------------------------------------- 311. Wall mountable version NC NC NC -------------------------------------------------------------------------------------------------------------------------- 312. System upgrade or modification can be done without rear access C C C -------------------------------------------------------------------------------------------------------------------------- 12 POWER SUPPLY 313. Nominal input voltage -48V C C C -------------------------------------------------------------------------------------------------------------------------- 314. Minimum accepted input voltage -38V -38V -38V -------------------------------------------------------------------------------------------------------------------------- 315. Maximum accepted input voltage -75V -75V -75V -------------------------------------------------------------------------------------------------------------------------- 13 AVAILABILITY ----------------------------------------------------------------------...
CLIMATIC CONDITIONS. All the Substations where these Ampact Fired ‘C’ Wedge Boltless Connectors are to be installed are located in the level alluvial plains of the Punjab (Altitude not exceeding 1000 meters),where the climate conditions are as under:-
a) The temperature of air in shade varies from-10 degree c to 50 degree C.
b) The maximum outside temperature of air in sun is 60 degree C.
c) Maximum daily and yearly average ambient temperature is 45 degree C to 35 degree C.
d) The tropical monsoon rain conditions exist for about the four months in the year and the average annual rainfall is 250 cm. The maximum relative humidity may be of the order of 90-100%
CLIMATIC CONDITIONS. All the Substations where these Ampact Fired ‘C’ Wedge Boltless Connectors are to be installed are located in the level alluvial plains of the Punjab (Altitude not exceeding 1000 meters), where the climate conditions are as under:-
a) The temperature of air in shade varies from-10 degree c to 50 degree C.
b) The maximum outside temperature of air in sun is 60 degree C.
c) Maximum daily and yearly average ambient temperature is 45 degree C to 35 degree C.
d) The tropical monsoon rain conditions exist for about the four months in the year and the average annual rainfall is 250 cm. The maximum relative humidity may be of the order of 90-100%
e) Heavy dust storms/thunderstorms accompanied by lightening occur at frequent intervals. The maximum wind pressure may be of the order of 195 KG per
f) Heavily polluted atmosphere having acidic contents in air causing normal sulphonation. The sites are vermin infested.
CLIMATIC CONDITIONS. The climatic conditions under which the equipment shall operate satisfactory are as indicated in page (3) of General and Financial terms and conditions for supply of materials.
CLIMATIC CONDITIONS. The pins and Hardware fittings shall be suitable for being installed directly in air with power conductors L.T. single circuit/double circuit overhead distribution lines. These items, therefore, shall be suitable for satisfactory operation under the tropical climatic conditions listed below :
1. Location In the state of Rajasthan i) Maximum ambient air Temperature (deg.C) 50