Committed Capacity Sample Clauses

The Committed Capacity clause defines the minimum level of resources, services, or output that one party is obligated to provide or maintain under an agreement. In practice, this clause specifies a set quantity—such as bandwidth, storage, or production volume—that must be available or delivered throughout the contract term, regardless of actual usage. Its core function is to ensure predictability and reliability for both parties by guaranteeing a baseline level of service or supply, thereby reducing the risk of shortages or underperformance.
POPULAR SAMPLE Copied 1 times
Committed Capacity. Subject to the terms and conditions of this Agreement, beginning from the Start Date until the End Date, the transit capacity in the Pipeline System reserved by Carrier at the benefit of Shipper, from the Delivery Point to the Redelivery Point, shall be equal to the committed capacity (the “Committed Capacity”), expressed in MWh/h and set out in the relevant TSC.
Committed Capacity. If the Beneficiary Firm fails to achieve the Committed Capacity as specified in Schedule - M, the Government shall have the right to deduct from the Subsidy payable under Clause 11.1, 2 (two) times the Subsidy due and payable corresponding to the shortfall in the Committed Capacity. By way of illustration and for the avoidance of doubt, the deduction in the Subsidy shall be computed as follows: If the Committed Capacity is 10 GWh, and the Beneficiary Firm achieves production / sale of 8 GWh, the Government shall deduct Subsidy payable for 2 * (10 - 8) = 4 GWh. The Beneficiary Firm would, under such circumstance, be paid Subsidy for (10 - 4) = 6 GWh of capacity, notwithstanding commissioning of 8 GWh.
Committed Capacity. The Committed Capacity shall be [_ _] kW, unless modified in‌ accordance with Section 8.2. The Committed Capacity shall be made available at the Point of Delivery from the Commencement of Service Date through the remaining Term of this Agreement.
Committed Capacity. PSL will reserve supply capacity in order to be able to supply Allegro with up to one hundred and ten percent (110%) of Allegro’s forecasted volumes as provided to PSL pursuant to the first sentence of Section 3.1.”
Committed Capacity. Upon the purchase and installation of the equipment in accordance with Section 8 of this Agreement, SABC shall provide ▇▇▇▇▇-▇▇▇▇▇▇ [ * ] of
Committed Capacity. Thirty-eight thousand kilowatts (38,000 kW) of reliable electrical capacity made available to the Company at the Metering Point under the Company Dispatch of which eight thousand kilowatts (8,000 kW) is provided pursuant to this Agreement and thirty thousand kW (30,000 kW) is provided pursuant to the Current PPA from the Existing Facility. Company Dispatch - The Company’s right, through supervisory equipment or otherwise, to direct or control both the capacity and the energy output of the Facility consistent with this Agreement, which dispatch shall include real power, reactive power, voltage regulation targets, the ramp rate setting, and other characteristics of such energy output whose parameters are normally controlled or accounted for in a utility dispatching system or specified in this Agreement.
Committed Capacity. (i) High Falls shall provide Boston Beer with annual production capacity (either Brewed Capacity or Packaged Capacity) at the Brewery (the "Annual Committed Capacity") of [*] barrels guaranteed available, as adjusted as set forth herein. Beginning [*], the Annual Committed Capacity for each calendar year of the Term shall be the greater of [*]% of the capacity used in the previous year and [*] barrels, provided that the maximum committed Brewed Capacity shall be [*] barrels and the maximum committed Packaged Capacity shall be [*] barrels per annum. It is the understanding of the parties that Boston Beer's [*] Products will be packaged on High Fall's # 2 bottling line, unless otherwise mutually agreed to in writing by the Parties. (ii) The Parties shall work together mutually to optimize the capacity utilization of the Brewery, and improve the tank utilization and brew house utilization of Boston Beer Products, provided that this shall not require Boston Beer to change process parameters affecting beer quality, taste or image in Boston Beer's sole discretion, nor shall this effort require specific investment by Boston Beer.
Committed Capacity. INFINEON agrees to commit the following capacity of wafer starts per week to APT: [*]
Committed Capacity 

Related to Committed Capacity

  • Maximum Capacity The Sick Leave Bank shall accumulate unused Bank days from year to year to a maximum capacity which shall not exceed double the number of eligible employees as defined in the above Section C, Eligibility for Membership.

  • Contract Capacity The electric power producing capability of the Generating Facility which is committed to Edison.

  • FREQUENCY AND CAPACITY LEVELS No restriction on frequency, capacity or aircraft types

  • Power and Capacity Each Shareholder has the power, authority and capacity to enter into this Agreement and to consummate the transactions contemplated hereby. This Agreement constitutes each Shareholder’s valid, legal and binding obligation and is enforceable against such Shareholder in accordance with its terms, subject, however, as to enforcement, to bankruptcy, insolvency, fraudulent transfer, moratorium and similar laws of general applicability relating to or affecting creditors’ rights;

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.2.1 Local circuit switching capability is defined as all line-side and trunk-side facilities, plus the features, functions, and capabilities of the switch. The features, functions, and capabilities of the switch shall include the basic switching function of connecting lines to lines, lines to trunks, trunks to lines, and trunks to trunks. Local circuit switching includes all vertical features that the switch is capable of providing, including custom calling, custom local area signalling service features, and Centrex, as well as any technically feasible customized routing functions. 4.2.2 Notwithstanding BellSouth’s general duty to unbundle local circuit switching, BellSouth shall not be required to unbundle local circuit switching for ▇▇▇▇ when ▇▇▇▇: (1) serves an End User with four (4) or more voice-grade (DS0) equivalents or lines served by BellSouth in Zone 1 of one of the following MSAs: Atlanta, GA;