Ordering and Provisioning 53.3.1 CenturyLink will provide necessary ordering and provisioning business process support as well as those technical and systems interfaces as may be required to enable CLEC to provide resale services, including the functions, features, and capabilities of such services, and Unbundled Network Elements. If CenturyLink deploys any enhanced electronic capability CenturyLink will notify CLEC of availability and CLEC shall use the processes for performing transaction(s) to the extent practicable and the use of any other interface or process will be discontinued. 53.3.2 The Parties agree that orders for services under this Agreement will not be submitted or accepted until thirty (30) Days after the completion of all account establishment activities, including but not limited to, the documents and information subscribed in Section 45.1, unless the Parties mutually agree upon a different date based on the specific circumstances of the Parties’ relationship. 53.3.3 Except as specifically provided otherwise in this Agreement, pre- ordering, ordering and provisioning of resold services shall be governed in accordance with CenturyLink’s Standard Practices. 53.3.4 CenturyLink will provide provisioning intervals and procedures for design and complex services on a nondiscriminatory basis. Complex Service Order charges pursuant to Tariff terms may apply. 53.3.5 Where Technically Feasible, the NEAC will coordinate support for all designed and/or complex services provided to CLEC. 53.3.6 To the extent required by Applicable Law, and upon request from CLEC, employing CenturyLink’s LSR, CenturyLink will provide blocking of 700, 900, and 976 services, or other services of similar type as may now exist or be developed in the future, and shall provide Billed Number Screening (BNS), including required LIDB updates, or equivalent service for blocking completion of bill-to-third party and collect calls, on a line, PBX, or individual service basis. Blocking shall be provided to the extent (a) it is an available option for the Telecommunications Service resold by CLEC, or (b) it is Technically Feasible when requested by CLEC as a function of Unbundled Network Elements. 53.3.7 When ordering a resale service via an LSR Service Order, CLEC may order separate interLATA and IintraLATA service providers (i.e., two PICs) on a line or trunk basis, and CLEC agrees to pay the applicable Service Order and PIC charges associated with such order. CenturyLink will accept PIC change orders for IntraLATA toll and long distance services through the service provisioning process. 53.3.8 The standard Service Order charges as listed in the Table 1 of this Agreement shall apply to all orders.
Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.
Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Freedom has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Freedom. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Freedom (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Freedom, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Freedom will then have the option of paying the one-time SC rates to place the Loop.
Connecting Transmission Owner’s Scope of Work and Responsibilities The Connecting Transmission Owner will design, construct, own, operate and maintain all Connecting Transmission Owner’s Interconnection Facilities, except as otherwise stated above and in the Project Specific Specifications. The Connecting Transmission Owner will complete all engineering reviews, field verifications and witness testing, etc. in accordance with the ESBs and the Project Specific Specifications. Connecting Transmission Owner shall provide the revenue metering CT/PT units and meter socket enclosure. The Connecting Transmission Owner shall: • provide, run, and wire both ends of the color-coded cable for the revenue metering instrument transformer secondary wiring; • perform all terminations; and • supply and install the meter. The revenue meter may require a communications link to the RTU. The Connecting Transmission Owner will specify and run those communications cables. The Connecting Transmission Owner shall complete all wiring, testing and commissioning of the RTU.
Selection of Subcontractors, Procurement of Materials and Leasing of Equipment The contractor shall not discriminate on the grounds of race, color, religion, sex, national origin, age or disability in the selection and retention of subcontractors, including procurement of materials and leases of equipment. The contractor shall take all necessary and reasonable steps to ensure nondiscrimination in the administration of this contract. a. The contractor shall notify all potential subcontractors and suppliers and lessors of their EEO obligations under this contract. b. The contractor will use good faith efforts to ensure subcontractor compliance with their EEO obligations.