Common use of Developer’s Attachment Facilities Clause in Contracts

Developer’s Attachment Facilities. Interconnection of the Large Generating Facility is achieved by means of the project substation named 9WU-BNL. The 9WU-BNL substation contains switching equipment to consolidate the field’s four (4) 13.8kV circuits, a 33MVA transformer to step the voltage to 69kV, and the required control and protection. Interconnection between 9WU- BNL and the LIPA 8ER Brookhaven Substation is achieved via a 69kV line which is direct buried and trenched approximately 3000ft. The Developer’s Attachment Facilities for the Large Generating Facility Project described in Appendix C of this Agreement are diagrammed in Figure A-1, of this Appendix A, and include:  Eight (8) 3-phase, 1200A (continuous), 25kA (interrupting), electrically operated, drawout type, vacuum 13.8kV circuit breakers including six (6) in ring bus configurations, one (1) spare, and one (1) at the switchgear output  One (1) 3-phase GOAB, 1200 A, 13.8kV switch (1) 33MVA collector transformer. Transformer is a step-up, 3-phase 13.8kV; 69kV buried ground tertiary winding, 19.8/26.4/33.0 MVA, ▇▇▇▇/▇▇▇▇/▇▇▇▇, ▇ ▇▇▇▇▇, ▇▇ ▇▇, ▇▇ Degree C rise, 67.65kV, Grd Wye to 13.8kV Wye with high voltage de-energized taps, buried grounded tertiary winding, 9% impedance at 19.8 MVA  Two (2) 3-phase GOAB, 1200A, 69kV switches  3000ft 69kV armored cable, 1-500MCM/phase  One (1) ION 8600 project meter  One (1) Shark meter for utility spare  One (1) 69kV circuit breaker, 2000A cont., 40kA int  All required protection  One (1) Control house  One (1) Battery room

Appears in 7 contracts

Sources: Generator Interconnection Agreement, Standard Large Generator Interconnection Agreement, Standard Large Generator Interconnection Agreement

Developer’s Attachment Facilities. Interconnection of the Large Generating Facility is achieved by means of the project substation named 9WU-BNL. The 9WU-BNL substation contains switching equipment to consolidate the field’s four (4) 13.8kV circuits, a 33MVA transformer to step the voltage to 69kV, and the required control and protection. Interconnection between 9WU- BNL and the LIPA 8ER Brookhaven Substation is achieved via a 69kV line which is direct buried and trenched approximately 3000ft. The Developer’s Attachment Facilities for the Large Generating Facility Project described in Appendix C of this Agreement are diagrammed in Figure A-1, of this Appendix A, and include: Eight (8) 3-phase, 1200A (continuous), 25kA (interrupting), electrically operated, drawout type, vacuum 13.8kV circuit breakers including six (6) in ring bus configurations, one (1) spare, and one (1) at the switchgear output One (1) 3-phase GOAB, 1200 A, 13.8kV switch (1) 33MVA collector transformer. Transformer is a step-up, 3-phase 13.8kV; 69kV buried ground tertiary winding, 19.8/26.4/33.0 MVA, ▇▇▇▇/▇▇▇▇/▇▇▇▇, ▇ ▇▇▇▇▇, ▇▇ ▇▇, ▇▇ Degree C rise, 67.65kV, Grd Wye to 13.8kV Wye with high voltage de-energized taps, buried grounded tertiary winding, 9% impedance at 19.8 MVA Two (2) 3-phase GOAB, 1200A, 69kV switches 3000ft 69kV armored cable, 1-500MCM/phase One (1) ION 8600 project meter One (1) Shark meter for utility spare One (1) 69kV circuit breaker, 2000A cont., 40kA int All required protection One (1) Control house One (1) Battery room

Appears in 2 contracts

Sources: Standard Large Generator Interconnection Agreement, Standard Large Generator Interconnection Agreement

Developer’s Attachment Facilities. Interconnection of the Large Generating Facility is achieved by means of the project substation named 9WU-BNL. The 9WU-BNL substation contains switching equipment to consolidate the field’s four (4) 13.8kV circuits, a 33MVA transformer to step the voltage to 69kV, and the required control and protection. Interconnection between 9WU- BNL and the LIPA 8ER Brookhaven Substation is achieved via a 69kV line which is direct buried and trenched approximately 3000ft. The Developer’s Attachment Facilities for the Large Generating Facility Project described in Appendix C of this Agreement are diagrammed in Figure A-1, of this Appendix A, and include: Eight (8) 3-phase, 1200A (continuous), 25kA (interrupting), electrically operated, drawout type, vacuum 13.8kV circuit breakers including six (6) in ring bus configurations, one (1) spare, and one (1) at the switchgear output One (1) 3-phase GOAB, 1200 A, 13.8kV switch (1) 33MVA collector transformer. Transformer is a step-up, 3-phase 13.8kV; 69kV buried ground tertiary winding, 19.8/26.4/33.0 MVA, ▇▇▇▇ONAN/▇▇▇▇ONAF/▇▇▇▇ONAF, ▇ ▇▇▇▇▇3 phase, ▇▇ ▇▇60 Hz, ▇▇ 65 Degree C rise, 67.65kV, Grd Wye to 13.8kV Wye with high voltage de-energized taps, buried grounded tertiary winding, 9% impedance at 19.8 MVA Two (2) 3-phase GOAB, 1200A, 69kV switches 3000ft 69kV armored cable, 1-500MCM/phase  One phase (1) ION 8600 project meter One (1) Shark meter for utility spare One (1) 69kV circuit breaker, 2000A cont., 40kA int All required protection One (1) Control house One (1) Battery room

Appears in 2 contracts

Sources: Standard Large Generator Interconnection Agreement, Standard Large Generator Interconnection Agreement

Developer’s Attachment Facilities. Interconnection of the Large Generating Facility is achieved by means of the project substation named 9WU-BNL. The 9WU-BNL substation contains switching equipment to consolidate the field’s four (4) 13.8kV circuits, a 33MVA transformer to step the voltage to 69kV, and the required control and protection. Interconnection between 9WU- BNL and the LIPA 8ER Brookhaven Substation is achieved via a 69kV line which is direct buried and trenched approximately 3000ft. The Developer’s Attachment Facilities for the Large Generating Facility Project described in Appendix C of this Agreement are diagrammed in Figure A-1, of this Appendix A, and include: Eight (8) 3-phase, 1200A (continuous), 25kA (interrupting), electrically operated, drawout type, vacuum 13.8kV circuit breakers including six (6) in ring bus configurations, one (1) spare, and one (1) at the switchgear output One (1) 3-phase GOAB, 1200 A, 13.8kV switch (1) 33MVA collector transformer. Transformer is a step-up, 3-phase 13.8kV; 69kV buried ground tertiary winding, 19.8/26.4/33.0 MVA, ▇▇▇▇/▇▇▇▇/▇▇▇▇, ▇ ▇▇▇▇▇, ▇▇ ▇▇, ▇▇ Degree C rise, 67.65kV, Grd Wye to 13.8kV Wye with high voltage de-energized taps, buried grounded tertiary winding, 9% impedance at 19.8 MVA Two (2) 3-phase GOAB, 1200A, 69kV switches 3000ft 69kV armored cable, 1-500MCM/phase  One phase (1) ION 8600 project meter One (1) Shark meter for utility spare One (1) 69kV circuit breaker, 2000A cont., 40kA int All required protection One (1) Control house One (1) Battery room

Appears in 1 contract

Sources: Standard Large Generator Interconnection Agreement