Common use of Developer’s Attachment Facilities Clause in Contracts

Developer’s Attachment Facilities. The Developer’s Attachment Facilities (“DAFs”) include all of the facilities between the Developer’s side of the Point of Change of Ownership (“PCO”) and the Large Generating Facility. The DAFs will be designed, constructed, operated, and maintained by the Developer. Developer shall design and construct the DAFs in accordance with applicable requirements of the Connecting Transmission Owner, as set out in the Connecting Transmission Owner’s Bulletin 86-01, dated October 3, 2011, and the Connecting Transmission Owner’s Bulk Power POI Guide, to the extent they are not inconsistent with the terms of this Agreement or the NYISO OATT. As depicted in Figure A-1 to this Appendix A, the DAFs will consist of the following major electrical and physical equipment: • Two (2) two-winding 84/112/135 MVA (ONAN/ONAF/ONAF), YnD1, 230/34.5 kV (Grounded Wye-Delta) transformers with an impedance of 11.0% on 135 MVA base; • Two (2) 230 kV breakers; • Phasor Measurement Unit (“PMU”); • Approximately 800 ft, 230 kV, cable to Canandaigua Substation; and • Structures.

Appears in 6 contracts

Sources: Interconnection Agreement, Interconnection Agreement, Interconnection Agreement

Developer’s Attachment Facilities. The Developer’s Attachment Facilities (“DAFs”) include all of the facilities between the Developer’s side of the Point of Change of Ownership (“PCO”) and the Large Generating Facility. The DAFs will be designed, constructed, operated, and maintained by the Developer. Developer shall design and construct the DAFs in accordance with applicable requirements of the Connecting Transmission Owner, as set out in the Connecting Transmission Owner’s Bulletin 86-01, dated October 3, 2011, and the Connecting Transmission Owner’s Bulk Power POI Guide, to the extent they are not inconsistent with the terms of this Agreement or the NYISO OATT. As depicted in Figure A-1 to this Appendix A, the DAFs will consist of the following major electrical and physical equipment: • Two One (21) two-winding 84/112/135 MVA (ONAN/ONAF/ONAF), YnD1, 230/34.5 kV (Grounded Wye-Delta) transformers transformer with an impedance of 11.0% on 135 MVA base; • One (1) three-winding 84/112/140 MVA (ONAN/ONAF/ONAF), YnYnD1, 230/34.5/13.8 kV (Grounded Wye-Grounded Wye-Delta) transformer with an impedance of 10.51% on 84 MVA base; • Two (2) 230 kV breakers; • Phasor Measurement Unit (“PMU”); • Approximately 800 ft, 230 kV, cable to Canandaigua Substation; and • Structures.

Appears in 1 contract

Sources: Standard Large Generator Interconnection Agreement

Developer’s Attachment Facilities. The Developer’s Attachment Facilities (“DAFs”) include all of the facilities between the Developer’s side of the Point of Change of Ownership (“PCO”) and the Large Generating Facility. The DAFs will be designed, constructed, operated, and maintained by the Developer. Developer shall design and construct the DAFs in accordance with applicable requirements of the Connecting Transmission Owner, as set out in the Connecting Transmission Owner’s Bulletin 86-01, dated October 3, 2011, and the Connecting Transmission Owner’s Bulk Power POI Guide, to the extent they are not inconsistent with the terms of this Agreement or the NYISO OATT. As depicted in Figure A-1 to this Appendix A, the DAFs will consist of the following major electrical and physical equipment: • Two OneTwo (212) two-winding 84/112/135 15084/200112/250135 MVA (ONAN/ONAF/ONAF), YnD1, 230/34.5 kV (Grounded Wye-Delta) transformers transformertransformers with an impedance of 11.015.511.0% on 135 250135 MVA base; • Two OneTwo (212) 230 kV breakersbreakerbreakers; • Phasor Measurement Unit (“PMU”); • Approximately 800 ft, 230 kV, cable to Canandaigua Substation; and • Structures.

Appears in 1 contract

Sources: Interconnection Agreement