Electrical Specifications. 12.1 Electricity supply will be provided as per terms and conditions indicated in Annexure - 2.The Licensee shall bear the amount of all the bills/costs for the electricity that may be consumed due to the operation of the advertisement panels /spaces allotted under this agreement. Licensee shall use energy efficient equipment. Advertiser shall follow the I.E. Rules, Acts for safety of equipment, public & Staff. 12.2 Rate of electricity chargeable from Licensee shall be at the rate at which Electricity Company / Distribution Company /Agency would levy on such a customer, had he obtained supply directly from Electricity Company / Distribution Company /Agency. DERC policy and Electricity Act (as amended from time to time) shall be applicable.
Electrical Specifications. 12.1 Electricity supply will be provided as per terms and conditions indicated in Annex -
Electrical Specifications. (a) Lighting: 2’x4’ recessed fluorescent lay-in 3” deep, 18 cell low iridescence Parabolic louver (1 fixture per 80SF), Energy efficient ballast. (b) The average electric load of the Premises shall not exceed sib (6) ▇▇▇▇▇ per usable square foot for power and three (3) ▇▇▇▇▇ per square foot for lighting.
Electrical Specifications. All electrical work shall be installed in accordance with the National Electrical Code, and the local building code. A "
Electrical Specifications. 8.1.1. Electricity supply will be provided as per terms and conditions indicated in Annexure - 3 : Rules and Guidelines for Release of Electric Power. The Licensee shall bear the amount of all the bills/costs for the electricity that may be consumed due to the operation of the advertisement panels /spaces allotted under this agreement. Licensee shall use energy efficient equipment. Advertiser shall follow the I.E. Rules, Acts for safety of equipment, public & Staff. 8.1.2. Rate of electricity chargeable from Licensee shall be at the rate at which Electricity Company / Distribution Company /Agency would levy on such a customer, had he obtained supply directly from Electricity Company / Distribution Company /Agency, MSEB policy and Electricity Act (as amended from time to time) shall be applicable.
Electrical Specifications. The detailed electrical specifications of Neg48DC/DC PSU are shown as below : Input Voltage Range -36 ~ -75VDC Inrush Current 75A max. Output Voltage (Volts) +12V Output Current (Amps) 33.3A(+12V) Max Power (Watt) –40°C to 55°C 450W, –40°C to 65°C 400W Output Voltage (Volts) +5VSB Output Current (Amps) 3A (+5VSB) Efficiency >88% @20% load, >91 @50% load, >89% @100% load Ripple P-P (mV) (max.) +12V:120, +5VSB:50 Total Regulation ±5% Hold-up Time (min.) 3mS@-48VDC Over Voltage Protection Latch off Over Current & Short Circuit Protection Auto Recovery Over Temperature Protection Auto Recovery FAN Failure Protection Hot Swap Load Sharing Hi-pot 2545VDC Operating Temperature Range –40°C to 65°C Storage Temperature Range –40°C to +70°C Humidity, Non-Condensing 0 to 95% RH EMI Meets FCC/CISPR 22 Class A(under 6dB) Specification
Electrical Specifications. Rated voltage 12 VDC Rated current 900mA, 1035mA, max. Rated power consumption 10.8W, 12.42W, max. Operating voltage range 10.2~13.2 VDC Starting voltage 10.2 VDC (25 degC) Operating temperature -40~70 degC Rated speed 25000 RPM+/-10% at rated voltage Air flow 31.3CFM, 27.6 CFM min. Static pressure 2.81 Inch-H2O, 1.96 Inch-H2O min. Acoustic noise 62.0 dB(A), 69.5 dB(A) max.
Electrical Specifications. Sheet resistance is measured at the center and (plus/minus) 100 mm from the center (see Figure 1 for sample size). The product is to have an average ohms/square value of less than 250. No individual reading is to exceed 270 ohms/square. This is measured on an LEI Contactless Conductivity Probe, Model 1000.
Electrical Specifications. All electrical equipments, wiring and provisions for the supply of power and lighting at MTM shall conform to the relevant standards laid down in the Indian Electricity Act 4. Fire Safety Conform to appropriate Fire Safety Standards as applicable 5. Statutory Agency Requirements Meet all requirements of the statutory agencies, including Ministry of Agriculture, Customs authorities, Ministry of Environment & Forests and the Pollution Control Board.
Electrical Specifications. (a) Lighting - Provide 2' x 4' LED - high efficiency light fixtures. (b) Power - Wall mounted duplex receptacles must meet all applicable codes. (c) The average electric load of the Demised Premises shall not exceed five (5) w▇▇▇▇ per square foot for lighting and power in office areas. Landlord will provide available service of 200A 277/480V, 3 phase, for Tenant's exclusive use. All other switchgear required is a function of the Workletter allowance. (re-use existing) (d) Landlord shall initially provide and install lamps and ballasts. Replacement of same shall be by Landlord, at Tenant's expense.