Equation 1: Base Assessment. Applies To All Products Calculate the base energy consumption by multiplying the measured energy consumption as specified in this test procedure by the hours per day values in the equations below. If the EUT does not include the capability for Auto Power Down, then use the first equation (a). If the product does include Auto Power Down capability, and it meets the requirements in Annex A (A.3; A.4), then use the second equation (b). PTV, PStandby and PAPD are power levels in ▇▇▇▇▇ as measured according to the measurement procedure set out in this Annex C. a) Annual energy (kWh/yr) for a product with no Auto Power Down kWh base = 0.365 x (TOn x PTV + TStandby x P Standby ) b) Annual energy (kWh/yr) for a product with Auto Power Down capability kWh base = 0.365 x (TOn x PTV + TStandby.x PStandby . + TAPD x PAPD)