Fast Track Screens Sample Clauses

Fast Track Screens. 8.1.1. Fast Track Screens, described in Attachment 3 hereto, provide for an initial review of Customer’s request for interconnection which evaluates whether the Customer’s request exceeds an acceptable level of impact to the FPL electric system, consistent with prudent utility practice. 8.1.2. In order to pass the Fast Track Screens, Customer’s interconnection shall not exceed established industry criteria, as set forth in the Interconnection Study Process and shall not require construction of Interconnection Facilities and Distribution Upgrades on FPL’s electric system. 8.1.3. If the Customer’s interconnection request passes the Fast Track Screens, the Customer’s request shall be approved and Customer will be provided an executable Interconnection Agreement.
Fast Track Screens. 2.1.1 For the successful interconnection of a proposed Member- owned renewable generation system, the Member-owned renewable generation system must utilize protective equipment (voltage, frequency, current…) in compliance with the terms of the most recent IEEE standard addressing Interconnection activities. 2.1.2 The proposed Member-owned renewable generation system, in aggregation with other generation on the distribution circuit, shall not contribute more than 10% to the distribution circuit’s maximum fault current at the point on the high voltage (primary) level nearest the proposed Point of Interconnection/Change of Ownership. 2.1.3 The proposed Member-owned renewable generation system, in aggregate with other generation on the distribution circuit, shall not cause any distribution devices and equipment (including, but not limited to, substation breakers, fuse cutouts, and line reclosers), or Member equipment on the system to exceed 87.5% of the short circuit interrupting capability; nor shall the interconnection be proposed for a circuit that already exceeds 87.5% of the short circuit interrupting capability. 2.1.4 This step includes a review of the type of electrical service provided to the Member, confirming that the generation output voltage will be appropriate for the existing transformer connection. Prudent steps shall be taken to limit the potential for creating voltage excursions on FKEC’s electric power system due to any issue on the Member’s system. 2.1.5 The plan needs to be approved by FKEC if the proposed Member-owned renewable generation system is to be interconnected on single-phase shared secondary, the aggregate generation capacity on the shared secondary, including the proposed Member-owned renewable generation system, shall not exceed 90% of the Member’s utility distribution service rating, conductor, or transformer. 2.1.6 The proposed Member-owned renewable generation system, in aggregate with other generation interconnected to the transmission side of a substation transformer feeding the circuit where the Member-owned renewable generation system proposes to interconnect shall not exceed 10 MW in an area where there are known, or posted, transient stability limitations to generating units located in the general electrical vicinity (e.g. three or four transmission busses from the Point of Interconnection/Change of Ownership). 2.1.7 No construction of facilities by FKEC on its own system shall be required to accommodate the Member-own...
Fast Track Screens. 8.1. Fast Track Screens, described in Attachment 1 hereto, provide for an initial review of Member’s request for interconnection which evaluates whether the Member’s request exceeds an acceptable level of impact to the FKEC electric system, consistent with prudent utility practice. 8.2. To pass the Fast Track Screens, Member’s interconnection shall not exceed established industry criteria, as set forth in the Interconnection Study Process and shall not require construction of Interconnection Facilities and Distribution Upgrades on FKEC’s electric system. 8.3. If the Member’s interconnection request passes the Fast Track Screens, the Member’s request shall be approved, and the Member will be provided an executable Interconnection Agreement. 8.4. In those instances, in which the Member-owned renewable generation does not pass the Fast Track Screens, and the Member wishes to continue with the project, FKEC will proceed with an Interconnection Study. In general, the purpose of the Interconnection Study will be to better determine what material adverse impacts the Member-owned renewable generation has on the FKEC system and what facilities will be required to resolve such impacts.
Fast Track Screens. 8.1.1 Fast Track Screens, described in Attachment 1 hereto, provide for an initial review of Member’s request for interconnection which evaluates whether the Member’s request exceeds an acceptable level of impact to the FKEC electric system, consistent with prudent utility practice. 8.1.2 In order to pass the Fast Track Screens, Member’s interconnection shall not exceed established industry criteria, as set forth in the Interconnection Study Process and shall not require construction of Interconnection Facilities and Distribution Upgrades on FKEC’s electric system. 8.1.3 If the Member’s interconnection request passes the Fast Track Screens, the Member’s request shall be approved and Member will be provided an executable Interconnection Agreement.

Related to Fast Track Screens

  • Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4. 5.7.2 BellSouth shall make available the following channelization systems and interfaces: 5.7.2.1 DS1 Channelization System: channelizes a DS1 signal into a maximum of twenty- four (24)

  • Programming Phase Schematic Design Phase: 2.2.1.3. Design Development Phase:

  • Sales During Pre-Settlement Period Notwithstanding anything herein to the contrary, if at any time on or after the time of execution of this Agreement by the Company and an applicable Purchaser, through, and including the time immediately prior to the Closing (the “Pre-Settlement Period”), such Purchaser sells to any Person all, or any portion, of any shares of Common Stock to be issued hereunder to such Purchaser at the Closing (collectively, the “Pre-Settlement Shares”), such Purchaser shall, automatically hereunder (without any additional required actions by such Purchaser or the Company), be deemed to be unconditionally bound to purchase, and the Company shall be deemed unconditionally bound to sell, such Pre-Settlement Shares to such Purchaser at the Closing; provided, that the Company shall not be required to deliver any Pre-Settlement Shares to such Purchaser prior to the Company’s receipt of the purchase price of such Pre-Settlement Shares hereunder; and provided further that the Company hereby acknowledges and agrees that the forgoing shall not constitute a representation or covenant by such Purchaser as to whether or not during the Pre-Settlement Period such Purchaser shall sell any shares of Common Stock to any Person and that any such decision to sell any shares of Common Stock by such Purchaser shall solely be made at the time such Purchaser elects to effect any such sale, if any.

  • Wire Unbundled DS1 Digital Loop This is a designed 4-wire Loop that is provisioned according to industry standards for DS1 or Primary Rate ISDN services and will come standard with a test point, OC, and a DLR. A DS1 Loop may be provisioned over a variety of loop transmission technologies including copper, HDSL-based technology or fiber optic transport systems. It will include a 4-Wire DS1 Network Interface at the End User’s location.

  • DNS name server availability Refers to the ability of a public-­‐DNS registered “IP address” of a particular name server listed as authoritative for a domain name, to answer DNS queries from an Internet user. All the public DNS-­‐registered “IP address” of all name servers of the domain name being monitored shall be tested individually. If 51% or more of the DNS testing probes get undefined/unanswered results from “DNS tests” to a name server “IP address” during a given time, the name server “IP address” will be considered unavailable.