FLOOR SLAB. All Tenant's with rest room facilities or food preparation areas shall install a floor slab waterproofing membrane in the Premises at Tenant's expense. All floor penetrations must be sleeved and waterproofed, except slabs on grade.
FLOOR SLAB. No penetrations shall be allowed for electrical outlets in floor slabs. All tenants with restroom facilities or food preparation areas shall install a floor slab waterproofing membrane in the Premises. All floor penetrations must be sleeved and waterproofed.
FLOOR SLAB. Landlord shall furnish a 4" thick slab on grade with smooth trowelled concrete surface. The floor elevation will be above the finished floor elevation in the mall areas adjacent to the Leased Premises.
FLOOR SLAB. The following is subject to structural requirements unknown at the time of authoring these specifications. Floor slab to be determined by soils and structural engineers. Floor slab to be a hard trowel finish. Control joints will be caulked. Floor will be installed utilizing a laser screed operation.
FLOOR SLAB. Where required, tenants shall provide 3000 PSI concrete ---------- slab with welded wire mesh reinforcing.
FLOOR SLAB. The floor is mesh reinforced concrete slab on a granular sub base. Uniformly distributed load of 30 Kn/m2 (600lbs/sq ft). Damp proof membrane under whole floor. Tolerance - Concrete Society Category 2 as defined in Technical Report No. 34. Surface Treatment - Power float finish with dust sealant and surface hardener.
FLOOR SLAB. The reinforced concrete floor slab shall be constructed as slab-on-grade over a minimum 4” thick aggregate base. Floor slab shall be smooth and level, and otherwise ready for carpet and tile finishes. Furnish and install the building facade, including brick, aluminum and glass windows, cast stone, EIFS cornice, and necessary supporting systems (including, but not limited to, metal studs and sheathing). For avoidance of doubt, the shell building construction will not include any windows on the rear wall of the Premises. Furnish and install R13 rigid insulation at the building perimeter (adjacent to exterior sheathing).
FLOOR SLAB a) The warehouse floor slab is to be constructed in accordance with geotechnical and structural engineer's recommendations. As a minimum, the floor slab shall be constructed of 6" thick, 4,000 psi reinforced concrete. Reinforcing shall be #3 reinforcing bars, 18" on center each way, Pad. located approximately 2" from top of slab. b) All concrete shall have a maximum allowable slump of 5" as tested by a qualified concrete testing agency at the site. c) Surface flatness tolerance in the warehouse area shall be 1/8" in 10'. d) Placement of concrete shall be done by utilizing a laser driven screed or a hydraulic power-driven screed in accordance with the structural engineer's recommendation. e) Slab control joints shall be saw cut at the optimum time to help reduce shrinkage cracking, but no less than 10 hours after the concrete has been placed. The maximum distance between saw cut control joints shall be 20' or an recommended by structural engineer. The joints shall be cut a maximum width of 1/8" and one-third the depth of the slab thickness. f) Slab construction joints arc to be dowelled with #5 smooth bars at 18" on center. g) All concrete mix designs shall be provided by a structual engineer and shall be reviewed and approved by the structural engineer and the selected independent testing agency prior to any concrete placement. h) All column shall have a formed diamond or round block out that will be poured and saw cut separately. i) No key ways of any type shall be allowed in the floor slab. j) A vapor barrier shall be provided under the office area.
FLOOR SLAB. A reinforced concrete slab will be provided for approximately the first two feet of the space. Uncompacted granular fill shall be provided for the balance of the space.
FLOOR SLAB. (a) Without limiting the provisions of Section 6 above, Purchaser acknowledges that it has reviewed the Floor Slab Reports and all matters in connection therewith, including without limitation the potential costs of correcting any known or unknown defects or movement in, or caused by the movement of, the floor slabs of the Property, any expansive soil problems and any moisture movement (the "FLOOR SLAB DEFECTS"), and that Seller has agreed to make available the maximum sum of Five Hundred Thousand Dollars ($500,000) to Purchaser as set forth herein to reimburse Purchaser for reasonable costs incurred by Purchaser during the Holdback Limitation Period to correct the Floor Slab Defects. (b) At the Closing, Escrow Agent, Purchaser and Seller or an affiliate of Seller (the "SELLER SUPPORT PARTY") shall enter into a Holdback Escrow Agreement (the "FLOOR SLAB HOLDBACK AGREEMENT") in the form attached hereto as EXHIBIT N, which Floor Slab Holdback Agreement shall establish an escrow account (the "FLOOR SLAB HOLDBACK ESCROW") to be maintained with the Escrow Agent and into which Seller or the Seller Support Party shall deposit the sum of Five Hundred Thousand Dollars ($500,000). The Floor Slab Holdback Agreement shall provide, among other things, that any funds remaining in the Floor Slab Holdback Escrow at the expiration of the Holdback Limitation Period shall then be refunded to Seller or the Seller Support Party, as applicable; provided that, if there exists as of the expiration of the Holdback Limitation Period a good faith dispute between Purchaser and Seller or the Seller Support Party with respect to an earlier withdrawal requested by Purchaser, the amount in dispute shall remain in the Floor Slab Holdback Escrow pending the resolution of the dispute consensually or by judicial proceeding. (c) Purchaser agrees that any and all liability of Seller and the Seller Support Party under this Section 21 or otherwise with respect to the Floor Slab Defects shall be limited exclusively to the funds available from time to time in the Floor Slab Holdback Escrow. (d) Any provision of this Agreement to the contrary notwithstanding, in the event that the Seller Support Party enters into the Floor Slab Holdback Agreement to be delivered at Closing and deposits into the Floor Slab Holdback Escrow the funds required to be deposited therein, Purchaser agrees that the entry into such agreement and the deposit of such funds by such affiliate shall automatically serve as a novat...