Foundation Walls. All foundation walls shall be poured concrete with reinforcing steel as shown on the construction drawings. Insulation around the interior perimeter of the foundation walls shall be provided in accordance with the requirements of the BOCA Building Code for allowable “U” factors and overall thermal performance. This insulation shall consist of 2” expanded polystyrene (EPS) rigid insulation board installed continuously around the perimeter of the building. The foundation wall insulation shall extend approximately two (2) feet below the finished floor elevation.
Appears in 1 contract
Foundation Walls. All foundation walls shall be poured concrete with reinforcing steel as shown on the construction drawings. Insulation around the interior perimeter of the foundation walls shall be provided in accordance with the requirements of the BOCA Building Code for allowable “"U” " factors and overall thermal performance. This insulation shall consist of 2” " expanded polystyrene (EPS) rigid insulation board installed continuously around the perimeter of the building. The foundation wall insulation shall extend approximately two (2) feet below the finished floor elevation.
Appears in 1 contract