GPA 2261 and 2145 Clause Samples

POPULAR SAMPLE Copied 2 times
GPA 2261 and 2145. The heating value of the Gas delivered by SABINE at the Delivery Point shall be determined by gas chromatograph. The composition of the Gas shall be continuously measured by on-line chromatographs. The Gross Heating Value of the Gas shall be calculated using results from the on-line chromatograph. The chromatographs will analyze all hydrocarbon components, up to and including at least the Nonanes+ group, and inerts having a concentration of greater than zero point zero zero two mole percent (0.002%). The determination of Gas composition shall be in accordance with the GPA Standard 2261 – Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography. All physical properties used in quality and quantity calculations shall be based on these compositional analyses and the component values published in GPA 2145, or the latest revision thereof. Water vapor content shall be included in the component analyses. The sample analysis cycle time shall be less than six (6) minutes. The maximum response time from sample probe to analyzer shall be four (4) minutes. In the event of failure of the on-line Gas chromatograph, chromatograph analysis of samples collected proportional to the flow through the meters shall be used. Auto-calibration of the Gas chromatograph shall be conducted on a weekly basis or as otherwise mutually agreed by the Parties.
GPA 2261 and 2145. The heating value of the Gas delivered by FLNG at the Delivery Point shall be determined by gas chromatograph. The composition of the Gas shall be continuously measured by on-line chromatographs. The Gross Heating Value of the Gas shall be calculated using results from the on-line chromatograph. The chromatographs will analyze all hydrocarbon components, up to and including at least the Nonanes+ group, and inerts having a concentration of greater than 0.002 mol percent. The determination of Gas composition shall be in accordance with the GPA Standard 2261 – Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography. All physical properties used in quality and quantity calculations shall be based on these compositional analyses and the component values published in GPA 2145, or the latest revision thereof. Water vapor content shall be included in the component analyses. The sample analysis cycle time shall be less than six minutes. The maximum response time from sample probe to analyzer shall be four minutes. In the event of failure of the on-line Gas chromatograph, chromatograph analysis of samples collected proportional to the flow through the meters shall be used. Auto-calibration of the Gas chromatograph shall be conducted on a weekly basis or as otherwise mutually agreed by the Parties.

Related to GPA 2261 and 2145

  • COVID-19 Employees of Contractor and/or persons working on its behalf, including, but not limited to, subcontractors (collectively, “Contractor Personnel”), while performing services under this Agreement and prior to interacting in person with City employees, contractors, volunteers, or members of the public (collectively, “In-Person Services”) must be fully vaccinated against the novel coronavirus 2019 (“COVID-19”). “Fully vaccinated” means that 14 or more days have passed since Contractor Personnel have received the final dose of a two-dose COVID-19 vaccine series (Moderna or Pfizer-BioNTech) or a single dose of a one-dose COVID-19 vaccine (▇▇▇▇▇▇▇ & ▇▇▇▇▇▇▇/▇▇▇▇▇▇▇) and all booster doses recommended by the Centers for Disease Control and Prevention. Prior to assigning Contractor Personnel to perform In-Person Services, Contractor shall obtain proof that such Contractor Personnel have been fully vaccinated. Contractor shall retain such proof for the document retention period set forth in this Agreement. Contractor shall grant medical or religious exemptions (“Exemptions”) to Contractor Personnel as required by law. If Contractor wishes to assign Contractor Personnel with Exemptions to perform In- Person Services, Contractor shall require such Contractor Personnel to undergo weekly COVID-19 testing, with the full cost of testing to be borne by Contractor. If Contractor Personnel test positive, they shall not be assigned to perform In-Person Services or, to the extent they have already been performing In-Person Services, shall be immediately removed from those assignments. Furthermore, Contractor shall immediately notify City if Contractor Personnel performing In-Person Services (1) have tested positive for or have been diagnosed with COVID-19, (2) have been informed by a medical professional that they are likely to have COVID-19, or (3) meet the criteria for isolation under applicable government orders.

  • Flexible Work Schedules An employee may request a modification of their current work schedule to another schedule. The Employer, or its designees, may approve or deny flexible work schedules and retain the responsibility for determining exemptions from, or terminations of, flexible work schedules which adversely affect the operation of the Minnesota Judicial Branch or the level of service to the public.

  • General specifications For the purpose of this Regulation, the vehicle shall fulfil the following requirements:

  • GPA Students who have followed the Advisement Plan attached to this agreement will receive the agreed upon hours of transfer credit towards the hours required for the B.S. degree. Credits remaining to complete the identified B.S. degree will be available in partnership with HCCC and SUNY Poly.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.