Lighting and Small Power Clause Samples

Lighting and Small Power. The following Lighting and Small Power works is applicable but not limited to: The illumination levels used are those recommended by 240-55714363: Coal Fired Power Stations Lighting and Small Power Installation Standard and SANS 10114-1: Interior lighting. a. These recommendations are specified as law under the South African National Building Regulations. b. Emergency lighting shall be according to 240-55714363: Coal Fired Power Stations Lighting And Small Power Installation Standard and SANS 10114-1: Interior lighting. c. The Occupational Health and Safety Act (OHS Act) specifies minimum illumination levels for safety. At no time shall the illumination level fall below these recommendations.
Lighting and Small Power. Should there be a requirement of lighting and small power: 1. The Contractor shall provide small power reticulation and architectural lighting design for the new pump house and rooms within the new pump house. Installation shall include equipment such as luminaries, dedicated panel boards, cabling and cable servitudes between devices and to equipment for connection to dedicated panel boards. 2. The Contractor shall design lighting and small power in accordance with Eskom standard 240- 55714363 Coal Fired Power Stations Lighting and Small Power Installation Standard.
Lighting and Small Power. Two electrical risers/rooms per floor include riser bus connections, provision for submetering, and distribution panels capable of delivering 86.08 w/m2 (8 w/ft2).
Lighting and Small Power. For the lighting works, the Contractor shall: • Perform detailed designs the lighting and small power circuits (distribution boards, plug sockets, etc.) • Confirm the compliance of the proposed layout, with the SANS 10114-1 and SANS 10142 requirements. Lighting design simulations using the photometric data of the proposed lights must be done • Ensure that interfacing with all the other system requirements of the plant/installation. • Produce all documentation and drawings

Related to Lighting and Small Power

  • Electrical Power Corporation shall provide Contractor with convenient access to electrical power required to perform the work. The electrical outlets used by Contractor shall be those designated or approved by Corporation.

  • Heating and Air Conditioning ▇▇▇▇▇▇ agrees to furnish to Lessee heating and air conditioning equipment and maintain same in satisfactory operating condition at all times for the Premises during the term of the Lease at the expense of Lessor. ▇▇▇▇▇▇ agrees that thermostats in the Premises will be set to maintain an average zone temperature of 75 degrees Fahrenheit during the heating and cooling seasons.

  • Heating, Ventilating and Air Conditioning General Office Area: The building shall be equipped with a combination heating, ventilation and air conditioning system. The system shall have ducted supply and return air. The space above the ceiling shall not be used as a supply or return plenum. The systems shall be sized in accordance with the

  • SHIPPING AND AIR TRANSPORT 1. Profits of an enterprise of a Contracting State from the operation of ships or aircraft in international traffic shall be taxable only in that State. 2. The provisions of paragraph 1 shall also apply to profits from the participation in a pool, a joint business or an international operating agency.

  • CUTTING AND PATCHING The Contractor shall be responsible for cutting, fitting or patching required to complete the Work or to make its parts fit together properly.