Mechanical and Electrical Sample Clauses

The 'Mechanical and Electrical' clause defines the standards, responsibilities, and requirements related to the mechanical and electrical systems within a project or property. It typically outlines the scope of work for installing, maintaining, or upgrading systems such as HVAC, plumbing, wiring, and other essential building services. This clause ensures that all mechanical and electrical components meet specified codes and performance criteria, thereby safeguarding the functionality and safety of the premises while clarifying the parties' obligations regarding these critical systems.
Mechanical and Electrical. The mechanical installation will commence when the MRF building roof and exterior shell are completed (target date is May 2010). BHS is responsible to perform mechanical and electrical installation so that the entire MRF system can be started and tested beginning mid-December 2010. Visual inspection will be conducted to ensure all guards and safety devices are installed properly. Inspect all transitions to confirm that any required belt scrapers, skirt walls, or sealing material is installed to prevent spillage. Confirm that the required staffing will be available for production. Confirm specific staffing requirements for pre and post sort staffing, front end loaders, supervision, forklift drivers, and baler operations. Begin training of all operational personnel. Training of maintenance personnel on required periodic maintenance. Enter the parameters for the 3 standard “menus” for each line. Testing of entire system in production mode. Ramp up to full production mode. Continue to adjust belt speeds, screen settings, and optical settings.
Mechanical and Electrical. Tenant's Plans shall contain all mechanical and electrical working drawings. Mechanical and electrical working drawings shall be prepared at Tenant's expense by engineers reasonably approved by Landlord. Tenant's Architect shall be responsible for coordination of all engineering work with Tenant's Plans.
Mechanical and Electrical. Subtenant's Plans shall contain all mechanical and electrical working drawings. Mechanical and electrical working drawings shall be prepared at Subtenant's expense by engineers reasonably approved by Sublandlord. Subtenant's Architect shall be responsible for coordination of all engineering work with Subtenant's Plans.
Mechanical and Electrical. Broad form boiler and machinery insurance on a blanket repair and replacement basis with limits per accident not less than the replacement cost of all leasehold improvements and of all boilers, pressure vessels, air conditioning equipment, miscellaneous electrical apparatus, electronic data processing equipment, and all other insurable objects owned or operated by Tenant or by others (other than Landlord) on behalf of Tenant in the Premises, or relating to or serving the Premises;
Mechanical and Electrical. The A/E shall employ mechanical and electrical engineers for the design and professional inspection of all mechanical work included in the Project, such as plumbing, fire protection, HVAC, control systems, electrical, fire detection, alarm systems and service for conveying systems.
Mechanical and Electrical. Employees working 12 hour shifts are not entitled to the provisions in sub- clauses 1-4. These Employees will, due to the on-call nature of their duties, be allowed a 30 minute paid meal break and two 15 minute paid tea breaks in each rostered shift.
Mechanical and Electrical. No exceptions.

Related to Mechanical and Electrical

  • Mechanical (i) Large scale mechanical details complete. (ii) Mechanical schedules for equipment completed. (iii) Completed electrical schematic for environmental cooling and exhaust equipment. (iv) Complete energy conservation calculations and report.

  • Electrical Provide drawings for the following systems: .1 Lighting including circuiting and luminaire identification and switching. Also provide illuminance computer printout for all indoor typical indoor spaces and parking lots. .2 Convenience outlets and circuiting, special outlets and circuiting, television outlets, and power systems and equipment. Provide riser diagrams for all electrical systems including master clock, intercom, fire alarm, ITV, computer networking/telephone. Also, provide for emergency and normal power distribution. Provide luminaire schedule. .3 Panel schedule may be in preliminary form but circuitry must be included. .4 Applicable installation details. .5 General legend and list of abbreviations. .6 Voltage drop computation for all main feeders. .7 Short circuit analysis .8 Provide 1/2" scale floor plan and wall elevations for all electrical rooms.

  • Systems The Servicer covenants that at the date hereof in respect of the software which is used by the Servicer in providing the Services, it shall for the duration of this Agreement:

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • Ventilation Where noxious or poisonous gases may accumulate, the City shall provide proper protection and ventilation. Proper lighting and ventilation shall be provided for all enclosed working spaces. All work in enclosed and confined spaces shall be performed in accordance with applicable Federal, State and local regulations. Spray painting shall be done only by qualified painters.