The Operating Tests clause defines the procedures and standards for testing equipment or systems to ensure they function as intended before being accepted or put into regular use. Typically, this clause outlines the specific tests to be performed, the conditions under which they are conducted, and the criteria for passing or failing. For example, it may require that machinery be run under full load for a set period or that safety features are verified in real-world scenarios. The core purpose of this clause is to verify operational readiness and compliance with contractual requirements, thereby reducing the risk of defects or failures after installation.
Operating Tests. Contractor shall conduct testing in accordance with Attachment S - Facility Testing Philosophy and the following operating tests to confirm the design meets the requirements of the Scope of Work. The procedures and acceptance criteria will be finalized by Contractor and reviewed by Owner prior to conducting the operating tests. The operating tests will be conducted before or after the Performance Tests as agreed by the Parties.
Operating Tests. Contractor shall conduct testing in accordance with Attachment 19 and the following operating tests to confirm the design meets the requirements of the Scope of Work. The procedures and acceptance criteria will be finalized by Contractor and reviewed by Owner prior to conducting the operating tests. The operating tests will be conducted before or after the Performance Tests as agreed by the Parties. Owner will be responsible for conducting regulatory compliance testing for all emissions and/or noise. Contractor will coordinate with Owner for any opportunity to conduct such tests concurrently.
Operating Tests. After issuance of the Completion Certificate, the Licensee may during a period of 30 calendar days (the "OPERATING TEST PERIOD") perform all such tests as it shall deem appropriate for the purposes of assessing compliance of the Licensee Equipment with the Final DFS under real operating conditions. Within 10 Business Days from the end of the Operating Test Period, the Licensee shall either (a) notify PW in writing of the existence of a Defect, in which case PW shall use all best endeavours to remedy such defects and, when resolved, shall issue a new Completion Certificate, or (b) express its full and final Acceptance of the Licensee System by returning to PW a copy of the Completion Certificate, countersigned by the Licensee. Irrevocable and unconditional Acceptance shall be deemed to have occurred, and the Licensee System shall be deemed accepted without qualifications or reservations, on the date that is 10 Business Days after the end of the Operating Test Period, unless the Licensee has, prior to such date, notified PW in writing of the existence of a Defect.
Operating Tests. Having successfully carried out the Putting into Service tests Contractor will perform the Operating Tests of all and each Hydroelectric Exploitation equipment and particularly, equipment of the Station, which must be according to the Execution Schedule and the provisions of Annex 13.
Operating Tests. After the installation is completed, and at such time as the Construction Inspector may direct, the contractor shall conduct operating tests for approval. The equipment shall be demonstrated to operate in accordance with the requirements herein. Each device subject to manual operation shall be operated at least five times, demonstrating satisfactory operation each time.

Related to Operating Tests

  • Right to Observe Testing Developer and Connecting Transmission Owner shall each notify the other Party, and the NYISO, in advance of its performance of tests of its Attachment Facilities. The other Party, and the NYISO, shall each have the right, at its own expense, to observe such testing.

  • Inspection/Testing In order to assess Supplier’s work quality and/or compliance with this Order, upon reasonable notice by Buyer: (a) all goods, materials and services related to the items purchased hereunder, including, raw materials, components, assemblies, work in process, tools and end products shall be subject to inspection and testing by Buyer, its customer, representative or regulatory authorities at all places, including sites where the goods are made or located or the services are performed, whether at Supplier’s premises or elsewhere; and (b) all of Supplier’s facilities, books and records relating to this Order shall be subject to inspection by Buyer or its designee. If specific Buyer and/or Buyer’s customer tests, inspection and/or witness points are included in this Order, the goods shall not be shipped without an inspector’s release or a written waiver of test/inspection/witness with respect to each such point; however, Buyer shall not be permitted to unreasonably delay shipment; and Supplier shall notify Buyer in writing at least twenty (20) days prior to each of Supplier’s scheduled final and, if applicable, intermediate test/inspection/witness points. Supplier agrees to cooperate with such/audit inspection including, completing and returning questionnaires and making available its knowledgeable representatives. Buyer’s failure to inspect or test goods, materials or services or Buyer’s failure to reject or detect defects by inspection or testing shall not relieve Supplier from its warranty obligations or any of its other obligations or responsibilities under this Order. Supplier agrees to provide small business as well as minority and/or women owned business utilization and demographic data upon request.

  • Performance Tests Contractor shall perform Performance Tests in accordance with Section 11.2 of the Agreement and Attachment S.

  • Inspections and Tests 26.1 The Supplier shall at its own expense and at no cost to the Procuring Entity carry out all such tests and/or inspections of the Goods and Related Services as are specified in the SCC. 26.2 The inspections and tests may be conducted on the premises of the Supplier or its Subcontractor, at point of delivery, and/or at the Goods' final destination, or in another place in Kenya as specified in the SCC. Subject to GCC Sub-Clause 26.3, if conducted on the premises of the Supplier or its Subcontractor, all reasonable facilities and assistance, including access to drawings and production data, shall be furnished to the inspectors at no charge to the Procuring Entity. 26.3 The Procuring Entity or its designated representative shall be entitled to attend the tests and/or inspections referred to in GCC Sub-Clause 26.2, provided that the Procuring Entity bear all of its own costs and expenses incurred in connection with such attendance including, but not limited to, all travelling and board and lodging expenses. 26.4 Whenever the Supplier is ready to carry out any such test and inspection, it shall give a reasonable advance notice, including the place and time, to the Procuring Entity. The Supplier shall obtain from any relevant third party or manufacturer any necessary permission or consent to enable the Procuring Entity or its designated representative to attend the test and/or inspection. 26.5 The Procuring Entity may require the Supplier to carry out any test and/or inspection not required by the Contract but deemed necessary to verify that the characteristics and performance of the Goods comply with the technical specifications codes and standards under the Contract, provided that the Supplier's reasonable costs and expenses incurred in the carrying out of such test and/or inspection shall be added to the Contract Price. Further, if such test and/or inspection impedes the progress of manufacturing and/or the Supplier's performance of its other obligations under the Contract, due allowance will be made in respect of the Delivery Dates and Completion Dates and the other obligations so affected. 26.6 The Supplier shall provide the Procuring Entity with a report of the results of any such test and/or inspection. 26.7 The Procuring Entity may reject any Goods or any part thereof that fail to pass any test and/or inspection or do not conform to the specifications. The Supplier shall either rectify or replace such rejected Goods or parts thereof or make alterations necessary to meet the specifications at no cost to the Procuring Entity, and shall repeat the test and/or inspection, at no cost to the Procuring Entity, upon giving a notice pursuant to GCC Sub- Clause 26.4. 26.8 The Supplier agrees that neither the execution of a test and/or inspection of the Goods or any part thereof, nor the attendance by the Procuring Entity or its representative, nor the issue of any report pursuant to GCC Sub-Clause 26.6, shall release the Supplier from any warranties or other obligations under the Contract.

  • Contractual and Operational Compliance Audits (a) ICANN may from time to time (not to exceed twice per calendar year) conduct, or engage a third party to conduct, contractual compliance audits to assess compliance by Registry Operator with its representations and warranties contained in Article 1 of this Agreement and its covenants contained in Article 2 of this Agreement. Such audits shall be tailored to achieve the purpose of assessing compliance, and ICANN will (a) give reasonable advance notice of any such audit, which notice shall specify in reasonable detail the categories of documents, data and other information requested by ICANN, and (b) use commercially reasonable efforts to conduct such audit during regular business hours and in such a manner as to not unreasonably disrupt the operations of Registry Operator. As part of such audit and upon request by ICANN, Registry Operator shall timely provide all responsive documents, data and any other information reasonably necessary to demonstrate Registry Operator’s compliance with this Agreement. Upon no less than ten (10) calendar days notice (unless otherwise agreed to by Registry Operator), ICANN may, as part of any contractual compliance audit, conduct site visits during regular business hours to assess compliance by Registry Operator with its representations and warranties contained in Article 1 of this Agreement and its covenants contained in Article 2 of this Agreement. ICANN will treat any information obtained in connection with such audits that is appropriately marked as confidential (as required by Section 7.15) as Confidential Information of Registry Operator in accordance with Section 7.15.