Physical Interface. The physical Point of Interconnection for Verizon and GNAPS for the End Point Fiber Meet will be the GNAPS’ fiber patch panel as designated by GNAPs. The Parties agree that Verizon has unescorted access to the Verizon side of the Fiber Patch Panel 24 hours a day, 7 days a week, without limitation, and that GNAPs has unescorted access to the GNAPs side of the Fiber Patch Panel 24 hours a day, 7 days a week, without limitation. Verizon will monitor and maintain the fiber optic electronics owned by Verizon. GNAPs will monitor and maintain the fiber optic electronics owned by GNAPs.
Physical Interface. 100BaseFX Payload Port 100BaseFX fiber, 1310 nm multimode 100BaseFX Ethernet interface used to receive and transmit user payload data. (ON/OFF build configurable)
Physical Interface. As set forth herein, a MAUL arrangement establishes a physical point of interface between the Verizon and ▇▇▇▇▇▇ networks through which ▇▇▇▇▇▇ may access unbundled local Loops served by the relevant Central Office. 3.1 ▇▇▇▇▇▇ is responsible for bringing its metallic facilities to the manhole or entrance facility (“Manhole Zero”) that is designated by Verizon, in its sole discretion, for the relevant Central Office. ▇▇▇▇▇▇ must gain access to Manhole Zero through the terms and conditions set forth in a separate agreement with Verizon in accordance with Section 9 of the Additional Services Attachment of the Agreement. Metallic facilities of ▇▇▇▇▇▇ that share any common power space or power conduit infrastructure will not be permitted to terminate in a Verizon Central Office. Where existing conduit or entrance facilities are not available, ▇▇▇▇▇▇ shall promptly pay to Verizon special construction charges that Verizon bills for such work as may be necessary. 3.2 ▇▇▇▇▇▇ shall bring its metallic cable to Manhole Zero and shall allow sufficient length to permit extension of the metallic cable to a point where it will be spliced to Verizon-furnished cable as set forth in the Final Plan (as hereinafter defined). 3.3 Verizon shall install (and may furnish, in accordance with the Final Plan) facilities from Manhole Zero to a Central Office protector frame, and shall terminate the facility in accordance with the terms hereof, and the Final Plan. 3.4 The physical point of interface between the Parties’ networks shall be in Manhole Zero (the “Point of Interface”). Verizon shall perform the cable splice (if any) in Manhole Zero and shall have exclusive control over all facilities on its side of the Point of Interface, and ▇▇▇▇▇▇ shall have exclusive control over all facilities on its side of the Point of Interface. ▇▇▇▇▇▇ shall be financially responsible, in accordance with the terms hereof and the Final Plan, for all facilities between the Point of Interface and the Main Distribution Frame at the relevant Central Office.
Physical Interface. The physical interface between the ECNs shall be 120 Ohm balanced termination provided by means of a twisted pair terminated on 10 pair Kröne insulation displacement terminating blocks. A loss of 6 dB is supported for both termination types.
Physical Interface. The physical interface shall be considered the fiber patch panel in the enclosure box located at the two locations noted in Section 2 above. The connector panels are approved and appropriate for the application and the size of cable to be connected. The connector panel locations provide 24-hour access to both Verizon and Charter. The connector panels are individually locked. The interconnecting carrier may splice its fiber to the fiber stub provided at the patch enclosure. The Parties will pay any additional cost for the connector panel and installation as set forth in Section 11. Verizon is to have access to the Verizon side of the MSFM and Charter will have access to the Charter side of the MSFM. Both parties shall provide monitoring and maintenance capability 24 hours a day for their respective side of the MSFM.
Physical Interface. The interconnection between the BT System and the Operator System shall be provided by a BT digital path that terminates on a BT Circuit Termination Unit (CTU) located within the building housing the Operator Switch. The BT CTU will present a G703 interface on two 75 ohm coaxial cables direct to either the Operator Switch or an Operator Digital Distribution Frame (DDF) which is co-located with the Operator Switch. The Point of Connection shall be the 75 ohm G703 coaxial connector at the BT end of the cables connecting the CTU to the Operator Switch (or co-located Operator DDF) (See Fig 1). The coaxial cables connecting the CTU to the Operator Switch shall have a loss not exceeding 6dB at 1024 kHz (see Fig 1). [FIGURE 1 GRAPHIC OMITTED] PAGE 34 of 61 35 SUBJECT TO CONTRACT --------------------------------------------------------------------------------

Related to Physical Interface

  • Technical Interfaces 3.2.6.1 The Interconnection facilities provided by each Party shall be formatted using either Alternate Mark Inversion (AMI) line code with Superframe format framing or Bipolar 8-Zero Substitution with Extended Superframe (B8ZS ESF) format framing or any mutually agreeable line coding and framing.

  • Firmware 7.1 The Supplier must deliver the equipment, Goods or hardware equipped with all the firmware required to use all the Goods or hardware’s functions. Any software embedded in the equipment, Goods or hardware, including the firmware, is provided to the Local Government with a license to use this software, with all license costs and royalties being included in the Fee Schedule (Schedule C). All firmware will be the most recent version available at the time of shipping.

  • Antivirus software All workstations, laptops and other systems that process and/or store PHI COUNTY discloses to CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY must have installed and actively use comprehensive anti-virus software solution with automatic updates scheduled at least daily.

  • Source Code 5.1 Nothing in this ▇▇▇▇ shall give to the User or any other person any right to access or use the Source Code or constitute any licence of the Source Code.