Piping Design Sample Clauses
The Piping Design clause outlines the requirements and standards for the planning, layout, and specification of piping systems within a project. It typically details the technical criteria, materials to be used, and compliance with relevant codes or industry standards, ensuring that all piping is designed for safety, efficiency, and compatibility with other systems. By establishing clear expectations for how piping should be designed, this clause helps prevent misunderstandings, ensures regulatory compliance, and reduces the risk of costly design errors or rework during construction.
Piping Design. 12255-4-08-4-002 rev00 Ash dam discharge lines assembly details Pipe diameter: 300 NB Material: carbon steel Wall thickness: 8 mm OD: 307.9 mm Number of pipelines: 4 Lengths Furthest points The following drawings reference the cross over access platforms, slopes and discharge line cross over assembly details 12255-4-08-4-003 rev 00 Ash dam cross over access platform and slopes 4&5 plan view 12255-04-08-004 rev 00 Ash dam discharge line cross over assembly details
3.1. 5Sub system design
Piping Design. Engineering Contractor shall prepare piping design & engineering deliverables and documentation. Contractor piping design & engineering activities shall, in addition to the above, encompass but not be limited to the following: 1. Electronic Design Model Page 30 of 63 This document, and the information it contains, are the property of or contains intellectual property that has been licensed to, Rio Grande LNG Train 4, LLC and/or its affiliates (“Company”). This document and its contents are “Confidential Information” as such term is used in relevant agreements between Company and the recipient. It may not be disclosed internally or to third parties without the prior, express approval of Company and in certain cases, its licensors. Company reserves all rights in relation to the misappropriation or misuse of this document and the Confidential Information that it contains. Please refer to your legal department regarding the terms and conditions of use. RGLNG T4 – ▇▇▇▇▇▇▇ – Train 4 Amended and Restated EPC Agreement AMENDED AND RESTATED EPC SCOPE OF WORK OF THE TRAIN 4 FACILITY RG2-NTD-000-PE-SOW-0001 Contractor shall generate a three-dimensional (3D) computer-aided design (CAD) electronic model for the Project. Database files for Contractor’s final 3D Model, with full attributes, shall be provided to Owner. [***].
Piping Design. Engineering Contractor shall prepare piping design & engineering deliverables and documentation. Contractor piping design & engineering activities shall, in addition to the above, encompass but not be limited to the following: 1. Electronic Design Model Contractor shall generate a three-dimensional (3D) computer-aided design (CAD) electronic model for the Project. Database files for Contractor’s final 3D Model, with full attributes, shall be provided to Owner. [***].
Piping Design. The Contractor shall perform the detail design for the new air supply line from the tap off from the existing control air line up to the connection to the fire protection valve. All piping modifications shall adhere to EN 13480. Specification for new piping: Pipe size: ND6 Connection to existing control air supply line: DN6 Carbon steel piping (ASME SA -▇▇▇ ▇▇ B),Schedule 40 to be used Air supply pressure 500kPa.
Piping Design