Proficiency Testing Clause Samples

The Proficiency Testing clause establishes requirements for evaluating the competence of individuals or organizations through standardized assessments. Typically, it mandates participation in periodic testing programs to ensure that personnel or laboratories meet specific performance standards, such as accuracy in laboratory results or technical skills in a given field. This clause serves to maintain quality and reliability by verifying ongoing proficiency, thereby reducing the risk of errors and ensuring compliance with industry or regulatory benchmarks.
Proficiency Testing. Faculty will be compensated thirty dollars ($30) for each proficiency test they grade which can only be graded by faculty. tests which can be scored by machines or by another employee with a master key will be scored in the Learning skills Center. When requested by the ▇▇▇▇/supervisor, faculty will be compensated one hun- dred dollars ($100) for each proficiency test they construct and grade. After the test has been constructed it will become the property of the College and will be kept on file in the ▇▇▇▇’▇ office.
Proficiency Testing. The Service Provider shall give each Officer and Custody staff a written examination consisting of at least 25 questions after each classroom-training course is completed. The Service Provider may give practical exercises when appropriate. The COTR shall approve the questions before the Service Provider can administer the examination. To pass any examination, each officer and custody staff must achieve a score of 80% or better. The Service Provider must provide the COTR with the eligible Officer or Custody staff’s completed exam before the Officer or Custody staff may be assigned to duties under the agreement. Should an employee fail the written test on the initial attempt, he or she shall be given additional training by the Service Provider and be given one additional opportunity to retake the test. If the employee fails to complete and pass the test the second time, the Service Provider shall remove the employee from duties on this agreement.
Proficiency Testing. The contractor shall give a written examination following each training class to display proficiency. To pass any examination, employees must achieve a minimum of 80 percent. Should an employee fail the written test on the initial attempt, the employee shall be given additional training and be given one additional opportunity to retake the test. If the employee fails the second attempt, the contractor shall remove the employee from the contract and immediately advise the COR. All training certifications will be stored the respective contract employee’s file.
Proficiency Testing. Teachers shall have access to all proficiency test results for their students. 153.02 Proficiency test results are a measurement of student learning. The current political climate requires the staff, the Administration, and the Board to take all appropriate measures possible to maintain and improve our stature and credibility with the public as regard proficiency test results. Proficiency test results shall not be part of the teacher evaluation process.
Proficiency Testing. Retention/Promotion of Pupils
Proficiency Testing. Core Methods (chemical) Proficiency Testing- Chemical Core Annual Proportion of LRN-C proficiency tests (core methods) successfully passed by PHEP-funded laboratories Table 1.8. Sample Collection, Packing, and Shipping (chemical) Sample Collection, Packing, and Shipping (SCPaS) Chemical Annual Ability of PHEP-funded LRN-C laboratories to collect, package, and ship samples properly during LRN exercise Table 1.9. Surge Capacity Exercise (chemical) Surge Capacity Exercise Chemical Annual Ability of each PHEP-funded LRN-C Level 1 laboratory to process and report results to CDC for 500 samples during the LRN Surge Capacity Exercise Table 1.10. Communication between PHEP-funded Laboratory and Sentinel Clinical Laboratories (Biological) a. Total b. Advanced, if defined c. Basic, if defined
Proficiency Testing. Additional Methods (chemical) Proficiency Testing- Chemical Additional Annual Proportion of LRN-C proficiency tests (additional methods) successfully passed by PHEP-funded laboratories

Related to Proficiency Testing

  • Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester. 7.2.2 No later than thirty (30) Days prior to the earlier of the Scheduled Substantial Completion Date or Substantial Completion, Design-Builder shall provide to Owner for review a detailed testing plan for the Performance Tests (other than for air emissions). Owner and Design-Builder shall agree upon a testing plan that shall be consistent with the Performance Test Protocol contained in Exhibit A hereto. After such agreement has been reached, Design-Builder shall notify the Owner five (5) business days prior to the date Design-Builder intends to commence the Performance Tests and shall notify the Owner upon commencement of the Performance Tests. Owner and Independent Engineer each have the right to witness all testing, including the Performance Tests and any equipment testing, whether at the Site or at the Subcontractor’s or equipment supplier’s premises during the course of this Agreement. Notwithstanding the foregoing sentence, Owner shall bear the costs of providing a witness to any such testing and all such witnesses shall comply at all times with Design-Builder’s, Subcontractor’s or equipment supplier’s safety and security procedures and other reasonable requirements, and otherwise conduct themselves in a manner that does not interfere with Design-Builder’s, Subcontractor’s or equipment supplier’s activities or operations. 7.2.3 Design-Builder shall provide to Owner a Performance Test report (excluding results from air emissions testing), including all applicable test data, calculations and certificates indicating the results of the Performance Tests and, within five (5) business days of Owner’s receipt of such results, Owner, Independent Engineer and Design-Builder will jointly inspect such Work and review the results of the Performance Tests to verify that the Performance Guarantee Criteria have been met. If Owner or Independent Engineer reasonably determines that the Performance Guarantee Criteria have not been met, Owner shall notify Design-Builder the reasons why Owner determined that the Performance Guarantee Criteria have not been met and Design-Builder shall promptly take such action or perform such additional work as will achieve the Performance Guarantee Criteria and shall issue to the Owner another notice in accordance with Section 7.2.2; provided however that if the notice relates to a retest, the notice may be provided no less than two (2) business days prior to the Performance Tests. Such procedure shall be repeated as necessary until Owner and Independent Engineer verifies that the Performance Guarantee Criteria have been met. 7.2.4 If Owner, for whatever reason, prevents Design-Builder from demonstrating the Performance Guarantee Criteria within thirty (30) Days of Design-Builder’s notice that the Plant is ready for Performance Testing, then Design-Builder shall be excused from demonstrating compliance with the Performance Guarantee Criteria during such period of time that Design-Builder is prevented from demonstrating compliance with the Performance Guarantee Criteria; provided however that Design-Builder will be deemed to have fulfilled all of its obligations to demonstrate that the Plant meets the Performance Guarantee Criteria should such period of time during which Design-Builder is prevented from demonstrating the Performance Criteria exceed thirty (30) Days or extend beyond the Final Completion Date.

  • Random Testing Notwithstanding any provisions of the Collective Agreement or any special agreements appended thereto, section 4.6 of the Canadian Model will not be applied by agreement. If applied to a worker dispatched by the Union, it will be applied or deemed to be applied unilaterally by the Employer. The Union retains the right to grieve the legality of any imposition of random testing in accordance with the Grievance Procedure set out in this Collective Agreement.

  • Inspection/Testing In order to assess Supplier’s work quality and/or compliance with this Order, upon reasonable notice by Buyer: (a) all goods, materials and services related to the items purchased hereunder, including, raw materials, components, assemblies, work in process, tools and end products shall be subject to inspection and testing by Buyer, its customer, representative or regulatory authorities at all places, including sites where the goods are made or located or the services are performed, whether at Supplier’s premises or elsewhere; and (b) all of Supplier’s facilities, books and records relating to this Order shall be subject to inspection by Buyer or its designee. If specific Buyer and/or Buyer’s customer tests, inspection and/or witness points are included in this Order, the goods shall not be shipped without an inspector’s release or a written waiver of test/inspection/witness with respect to each such point; however, Buyer shall not be permitted to unreasonably delay shipment; and Supplier shall notify Buyer in writing at least twenty (20) days prior to each of Supplier’s scheduled final and, if applicable, intermediate test/inspection/witness points. Supplier agrees to cooperate with such/audit inspection including, completing and returning questionnaires and making available its knowledgeable representatives. Buyer’s failure to inspect or test goods, materials or services or Buyer’s failure to reject or detect defects by inspection or testing shall not relieve Supplier from its warranty obligations or any of its other obligations or responsibilities under this Order. Supplier agrees to provide small business as well as minority and/or women owned business utilization and demographic data upon request.