RESPONSE CAPABILITIES Sample Clauses

The RESPONSE CAPABILITIES clause defines the obligations and procedures for how a party must respond to specific incidents, requests, or situations outlined in the agreement. Typically, this clause details the required timeframe for response, the types of incidents covered (such as security breaches or service outages), and the communication channels to be used. Its core function is to ensure that both parties have clear expectations regarding timely and effective responses, thereby minimizing confusion and mitigating potential risks associated with delayed or inadequate action.
RESPONSE CAPABILITIES. STATEWIDE MUTUAL AID AGREEMENT (SMAA)
RESPONSE CAPABILITIES. Contacts - The Recipient shall maintain current county emergency management and other contacts through the Division’s SharePoint portal available at ▇▇▇▇▇://▇▇▇▇▇▇.▇▇▇▇▇▇▇▇▇▇▇▇▇▇▇.▇▇▇. From the Portal main page, click “County Links”, then pulldown and select “Update County Contacts.” This information includes the following but not limited to: • County Director and Alternate contacts • State Mutual Aid Agreement contacts • County Operations Section • County Logistics Section • County Planning Section WebEOC Site Identification - The Recipient shall upload current Site Data to WebEOC available at ▇▇▇▇▇://▇▇▇.▇▇▇▇▇▇▇▇▇▇▇▇▇▇▇.▇▇▇. WebEOC site Identification data includes: • Through the SERT County Emergency Sites Board via the State’s WebEOC Instance or through your local instance if you are subscribed to this Board - location and attribute information of all pre-identified -- o County Staging Areas (CSAs) o County Points of Distribution (PODs) Attribute information shall include at a minimum: Site Name, Site Type, Site Address, Full Address with Latitude/Longitude in decimal degrees, Primary Contact (name, e-mail, and mobile phone) Secondary Contact (name, e-mail, and mobile phone), does the location have a loading dock, can the location accept 53ft trailers, if so, how many?. Site address shall be mapped by clicking on Map icon to verify address. The following Site Information is optional: • Picture attachment of Site. • Comments regarding access, transportation routes or any planning information. • Sites should be located adjacent to a major highway and have the ability to establish safe one- way traffic through the compound and reasonably secured. County Staging Areas must also be located in a region that can support countywide relief operations. • For coastal counties, sites should not be located in a “Zone A” Evacuation Zone where possible, exceptions can be made. • PODs should not be nearby a business that has water and food for sale. • Counties should focus on placing PODS in outlying areas where these types of stores are not located in-order to ensure that resources are available in those areas. • For coastal counties, sites should not be located in a “Zone A” Evacuation Zone where possible, exceptions can be made.
RESPONSE CAPABILITIES. EQUIPMENT INVENTORY AND AVAILABILITY Reporting Requirements: Quarter 1 Quarter 2 Quarter 3 Quarter 4 N/A N/A Deliverables Due Submit – Updates Only

Related to RESPONSE CAPABILITIES

  • Capabilities A. The Parties agree that the DRE must possess the legal, technical, and financial capacity to: (1) Accept and expend non-federal funds consistent with Section 4.2.4; (2) Accept transfer of the FERC license and title for the Facilities from PacifiCorp; (3) Seek and obtain necessary permits and other authorizations to implement Facilities Removal; (4) Enter into appropriate contracts and grant agreements for effectuating Facilities Removal; (5) Perform, directly or by oversight, Facilities Removal; (6) Prevent, mitigate, and respond to damages the DRE or any of its contractors, subcontractors, or assigns cause during the course of Facilities Removal, and, consistent with Applicable Law, respond to and defend associated liability claims against the DRE or any of its contractors, subcontractors, or assigns, including costs thereof and any judgments or awards resulting therefrom; (7) Carry the required insurance and bonding set forth in Appendix L to respond to liability and damages claims associated with Facilities Removal against the DRE or any of its contractors, subcontractors, or assigns; (8) Meet the deadlines set forth in Exhibit 4; and (9) Perform such other tasks as are reasonable and necessary for Facilities Removal. B. Before the DRE and PacifiCorp file the joint application to transfer the license for the Facilities, the DRE will Timely demonstrate to the reasonable satisfaction of the States and PacifiCorp that it possesses the legal, technical, and financial capacity to accomplish the tasks in Sections 7.1.2.A(1) through (5), (8), and (9). PacifiCorp and the States will consult if the DRE fails to make the demonstration required in this subsection. C. Within six months of the DRE’s execution of the Settlement, the DRE will include in an informational filing in the FERC license transfer proceeding proof that it possesses the legal, technical, and financial capacity to accomplish the tasks in Sections 7.1.2.A(6) and (7). This filing will include documentation that the DRE meets the requirements of Parts II, III, and IV of Appendix L and is capable of fulfilling its obligations under Section 7.1.3. The DRE will not provide the filing if either of the States or PacifiCorp objects to the filing after a reasonable opportunity to review before submission to FERC. The six-month deadline may be changed by agreement of the DRE, the States, and PacifiCorp. The Parties will Meet and Confer if the DRE fails to provide the informational filing to FERC.

  • Interconnection Customer (1) Interconnection Customer shall construct and, unless otherwise indicated, shall own, the following Interconnection Facilities: None (2) In the event that, in accordance with the Interconnection Construction Service Agreement, Interconnection Customer has exercised the Option to Build, it is hereby permitted to build in accordance with and subject to the conditions and limitations set forth in that Section, the following portions of the Transmission Owner Interconnection Facilities which constitute or are part of the Customer Facility: None Ownership of the facilities built by Interconnection Customer pursuant to the Option to Build shall be as provided in the Interconnection Construction Service Agreement.

  • Interconnection Customer Provided Services The services provided by Interconnection Customer under this LGIA are set forth in Article 9.6 and Article 13.5. 1. Interconnection Customer shall be paid for such services in accordance with Article 11.6.

  • Subprocessing The data importer shall not subcontract any of its processing operations performed on behalf of the data exporter under the Clauses without the prior written consent of the data exporter. Where the data importer subcontracts its obligations under the Clauses, with the consent of the data exporter, it shall do so only by way of a written agreement with the subprocessor which imposes the same obligations on the subprocessor as are imposed on the data importer under the Clauses. Where the subprocessor fails to fulfil its data protection obligations under such written agreement the data importer shall remain fully liable to the data exporter for the performance of the subprocessor's obligations under such agreement.

  • Interconnection Customer Drawings Within one hundred twenty (120) days after the date of Initial Operation, unless the Interconnection Parties agree on another mutually acceptable deadline, the Interconnection Customer shall deliver to the Transmission Provider and the Interconnected Transmission Owner final, “as-built” drawings, information and documents regarding the Customer Interconnection Facilities, including, as and to the extent applicable: a one-line diagram, a site plan showing the Customer Facility and the Customer Interconnection Facilities, plan and elevation drawings showing the layout of the Customer Interconnection Facilities, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer's step-up transformers, the facilities connecting the Customer Facility to the step-up transformers and the Customer Interconnection Facilities, and the impedances (determined by factory tests) for the associated step-up transformers and the Customer Facility. As applicable, the Interconnection Customer shall provide Transmission Provider and the Interconnected Transmission Owner specifications for the excitation system, automatic voltage regulator, Customer Facility control and protection settings, transformer tap settings, and communications.