Revision of Local Operating Procedures. 7.1 The Parties agree to meet as requested by either Party to review and consider amendments to the Local Operating Procedures. Such meeting shall occur within one (1) calendar month of the request being made, unless otherwise agreed by the Parties acting reasonably. The Parties shall discuss and negotiate any such proposed amendments in good faith, and shall use reasonable endeavours to agree the extent of any such proposed amendments. For the avoidance of doubt, the provisions of Clause 3.1 shall apply to any such amendment. National Grid hereby notifies you that, due to a [constraint on the System][breach of the Gas Entry Conditions], the System is unable to accept, to the extent identified in this TFA, natural gas from the DFO’s connected delivery facility at the rate and/or amount specified in the latest DFN. The instantaneous delivery rate should not exceed the specified TFA rate. Units >>> MSCM/D MSCM/D MSC/D Yes/No DFO EoD (if different) The information contained in the facsimile is confidential and may be privileged. This facsimile is intended only for the DFO named above. If you are not the intended recipient any review, dissemination or copying of this facsimile is prohibited. If you have received this facsimile by accident, please notify the Network Manager immediately by telephone on ▇▇▇▇ ▇▇▇ ▇▇▇▇ 1. National Grid Shift Representative 1. Connected Delivery Facility and Individual System Entry Point(s) 1.1 The Delivery Facility is a Connected Delivery Facility. 1.2 The Individual System Entry Point(s) comprised in the System Entry Point are shown in the drawing attached as Attachment A to Schedule 1 2. Gas Entry Conditions 2.1 These Gas Entry Conditions shall apply at the System Entry Point. 2.2 Gas tendered for delivery by System Users to the System at the System Entry Point shall comply with the System’s statutory safety requirements, including any Legal Requirement regarding the composition of gas to be conveyed in the System (including without limitation, schedule 3 of the Gas Safety (Management) Regulations 1996).
Appears in 1 contract
Sources: Network Entry Agreement
Revision of Local Operating Procedures. 7.1 The Parties agree to meet as requested by either Party to review and consider amendments to the Local Operating Procedures. Such meeting shall occur within one (1) calendar month of the request being made, unless otherwise agreed by the Parties acting reasonably. The Parties shall discuss and negotiate any such proposed amendments in good faith, and shall use reasonable endeavours to agree the extent of any such proposed amendments. For the avoidance of doubt, the provisions of Clause 3.1 shall apply to any such amendment. Attachment B to Schedule 1 - DAILY FLOW NOTIFICATION National Grid hereby notifies you that, due to a [constraint on the System][breach of the Gas Entry Conditions], the System is unable to accept, to the extent identified in this TFA, natural gas from the DFO’s connected delivery facility at the rate and/or amount specified in the latest DFN. The instantaneous delivery rate should not exceed the specified TFA rate. Units >>> MSCM/D MSCM/D MSC/D Yes/No DFO EoD (if different) The information contained in the facsimile is confidential and may be privileged. This facsimile is intended only for the DFO named above. If you are not the intended recipient any review, dissemination di ssemination or copying of this facsimile is prohibited. If you have received this facsimile by accident, please notify the Network Manager immediately by telephone on ▇▇▇▇ ▇▇▇ ▇▇▇▇▇ Attachment D to Schedule 1 COMMUNICATIONS
1. National Grid Shift Representative
2. DFO Representative [Position] [DFO Name] [Address] Telephone: [ ] Facsimile: [ ] From: [DFO] Address: [ ] Fax: [ ] Tel: [ ] To: National Grid Address: [ ] Fax: [ ] Tel: [ ] Date: [ ] Time: [ ] Gas Day commencing 0600 hours on: [ ] Volume Delivered (MSCM): [XX.XXXXX] Energy Delivered (kWh): [XXX,XXX,XXX] Average Calorific Value (MJ/SCM): [XX.XX] Signature: Position: Attachment F to Schedule 1 NOTIFICATION OF MAINTENANCE – By Delivery Facility This form is used to notify National Grid of the maximum gas flow of which a Delivery Facility is capable, at the System Entry Point to the System, taking into account all information available to the DFO, concerning planned maintenance activities both onshore and offshore. This information is provided in good faith based upon best judgement of the DFO without liability. To be returned by 15th of each quarter: September (for that calendar year and the following calendar year) March and June (for that calendar year) In between each quarterly update any changes to previously communicated planned maintenance should be provided to National Grid (on the same proforma), as soon as they are known. To: Company Name National Grid Gas plc From: Company Name ABC Company
1. Connected Delivery Facility and Individual System Entry Point(s)
1.1 The Delivery Facility is a Connected Delivery Facility.
1.2 The Individual System Entry Point(s) comprised in the System Entry Point are shown in the drawing attached as Attachment A to Schedule 1
2. Gas Entry Conditions
2.1 These Gas Entry Conditions shall apply at the System Entry Point.
2.2 Gas tendered for delivery by System Users to the System at the System Entry Point shall comply with the System’s statutory safety requirements, including any Legal Requirement regarding the composition of gas to be conveyed in the System (including without limitation, schedule 3 of the Gas Safety (Management) Regulations 1996).
2.3 Gas tendered for delivery by System Users to the System at the System Entry Point shall not contain any solid, liquid or gaseous material which would interfere with the integrity or operation of the System or any pipeline connected to such System or any appliance which a consumer might reasonably be expected to have connected to the System. In addition, all gas delivered to the System at the System Entry Point shall be in accordance with the following values:
(a) Hydrogen Sulphide not more than 3.3 ppm.
(b) Total Sulphur not more than 15 ppm.
(c) Hydrogen Content not more than 0.1 mol%.
(d) Oxygen Content not more than 10 ppm.
(e) Hydrocarbon Dewpoint not more than minus two degrees Celsius (-2°C) at any pressure up to the delivery pressure provided in paragraph (p).
(f) Water Dewpoint not such as would cause a water dewpoint more than minus ten degrees Celsius (-10ºC) at the delivery pressure provided in paragraph (p).
(g) ▇▇▇▇▇ Number shall be between 47.2 MJ/SCM, and 51.41 MJ/SCM.
(h) Incomplete Combustion not more than 0.48. Factor (ICF) (i) Soot Index (SI) not more than 0.60.
Appears in 1 contract
Sources: Network Entry Agreement