Tower foundation Clause Samples

Tower foundation. Generators, diesel tanks, and shelters, and their respective foundations.
Tower foundation. Once the contract is awarded to the supplier, foundation loads will be made available for the supplier to commence with the construction of the foundations in strict accordance to general tower specification, 240- 59967638. Although foundation drawings has been provided with the tender documents, it shall be used for costing only. Should the contractor opt to use their own drawings they need to resubmit back to Eskom using their own format with company logo for approval. a) The following foundations types will be acceptable for use by Eskom: Self-Supporting Towers:  Raft Foundations (single concrete slab/ raft connected to base of tower) - on the surface or below natural ground level.  Individual pad foundations – individual concrete foundations per tower leg consisting of the column extended above ground, extending into pad and plinth below ground level.  Piled foundations- individual foundation per tower leg consisting of a pile cap connecting multiple piles. b) The following soil design parameters must be used for the construction of the foundation based on normal soil conditions.  normal soil – equal or better consistency than one encountered in stiff cohesive soil or dense cohesion less soils above the water tableminimum allowable soil bearing pressure - 150kPa  soil uplift frustum angle – 30 degrees The foundation is designed with a resistance factor of not less than 1.5 for uplift, sliding and overturning moments. These checks will be based on the serviceability loads indicated above. The foundation is designed for the maximum combinations of vertical compression, uplift, and horizontal shear loads acting at ground level. Maximum allowable displacement under ultimate load conditions shall be less than 20mm. The foundation concrete strength shall be in accordance with SANS 10100, based on ultimate foundation loads.

Related to Tower foundation

  • Foundation In their respective agreements, the parties have recommended that a temporary manpower/resource pool of permanent employees be set up to cover normal absences (Section 20 of the Agreement). The parties agree that the employees working in such a pool can also be used to cover peak activities or in other temporary situations that call for extra ▇▇▇▇▇▇▇.

  • University Any notice may be served upon the University by delivering it, in writing, to the University at the address set forth on the last page of this Agreement, by depositing it in a United States Postal Service deposit box with the postage fully prepaid and with the notice addressed to the University at the aforementioned address, or by sending a facsimile of it to the University facsimile number set forth on the last page of this Agreement.

  • Foundations nor shall the Contractor be responsible for correction of leaks resulting from said failure.

  • Technology Transfer Subject to the terms of the Development Supply Agreement, as soon as reasonably practicable, but in no event later than the fifth (5th) anniversary of the Effective Date, Alnylam shall initiate a technology transfer to MedCo, or to its Third Party manufacturer(s) of Licensed Product, selected by MedCo and reasonably acceptable to Alnylam, of Alnylam Know-How that is reasonably necessary or useful for the Manufacture of the Licensed Product, and shall make available its personnel on a reasonable basis to consult with MedCo or such Third Party manufacturer(s) with respect thereto, all at MedCo’s expense, including the Costs reasonably incurred by Alnylam in connection with such technology transfer activities. MedCo shall reimburse Alnylam such Costs incurred with respect to such Manufacturing technology transfer within [***] days after receipt of an invoice therefor. Alnylam and its Affiliates shall keep complete and accurate records in sufficient detail to enable the payments payable hereunder to be determined. Alnylam shall not be required to perform technology transfer to more than one Third Party manufacturer for each stage of the Licensed Product supply chain (i.e., Bulk Drug Substance, Bulk Drug Product and Finished Product). Promptly after MedCo’s written request, Alnylam shall use Commercially Reasonable Efforts to assign to MedCo any manufacturing agreement between Alnylam and a Third Party that is solely related to the manufacture of Licensed Products. Such assignment shall be subject to the terms and conditions of such agreement, including any required consents of such Third Party and MedCo’s written agreement to assume all the obligations of Alnylam under such agreement to be undertaken after such assignment, but Alnylam shall remain solely responsible for its obligations under such agreement arising prior to such assignment. Except as provided in the immediately preceding sentence, MedCo shall be solely responsible for contracting with such Third Party manufacturer (and any other Third Party manufacture to whom Alnylam has initiated technology transfer as set forth in this Section 5.3) for the supply of such Licensed Product and Alnylam shall have no obligations under such agreement between MedCo and such Third Party manufacturer. Alnylam shall use Commercially Reasonable Efforts to obtain any such consent in a form reasonably acceptable to MedCo.

  • Alignment with Modernization Foundational Programs and Foundational Capabilities The activities and services that the LPHA has agreed to deliver under this Program Element align with Foundational Programs and Foundational Capabilities and the public health accountability metrics (if applicable), as follows (see Oregon’s Public Health Modernization Manual, (▇▇▇▇://▇▇▇.▇▇▇▇▇▇.▇▇▇/oha/PH/ABOUT/TASKFORCE/Documents/public_health_modernization_man ual.pdf): a. Foundational Programs and Capabilities (As specified in Public Health Modernization Manual) b. The work in this Program Element helps Oregon’s governmental public health system achieve the following Public Health Accountability Metric, Health Outcome Measure: c. The work in this Program Element helps Oregon’s governmental public health system achieve the following Public Health Accountability Metric, Local Public Health Process Measure: