Trunk Configuration – AT&T-2STATE Clause Samples

Trunk Configuration – AT&T-2STATE. 4.5.2.1 When Interconnecting at AT&T-2STATE’s digital End Offices, the Parties have a preference for use of Bipolar 8 Zero Substitution Extended Super Frame (B8ZS ESF) two-way trunks for all traffic between their networks. Where available, such trunk equipment will be used for Local Interconnection Trunk Groups. Where AMI trunks are used, either Party may request upgrade to B8ZS ESF when such equipment is available. 4.5.2.2 When interconnecting at AT&T CALIFORNIA’s DMS Access Tandem(s), 64CCC data and voice traffic may be combined on the same two-way Local Interconnection Trunk Group. 64 CCC data and voice traffic must be on separate two-way Local Interconnection Trunk Groups and not combined at AT&T CALIFORNIA’s 4E Access Tandems.

Related to Trunk Configuration – AT&T-2STATE

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • AIRCRAFT CONFIGURATION The guarantees defined below ("the Guarantees") are applicable to the A330-200 Aircraft as described in the Technical Specification ***, as amended by the Specification Change Notices ("SCN's") for:

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Connectivity User is solely responsible for providing and maintaining all necessary electronic communications with Exchange, including, wiring, computer hardware, software, communication line access, and networking devices.