The Vertical Circulation clause defines the requirements and standards for elements such as stairs, elevators, and escalators that facilitate movement between different floors of a building. It typically outlines specifications regarding their design, placement, accessibility, and safety features to ensure efficient and compliant movement for occupants. This clause is essential for ensuring that buildings are navigable and accessible, addressing both regulatory compliance and user convenience.
Vertical Circulation. All continuous vertical components (i.e., non‐structural shafts, architectural stairs, ramps, conveying systems, handrails and guardrails) shall be accurately depicted and shall include the necessary intelligence to produce accurate plans, elevations and sections in which such design elements are referenced.
Vertical Circulation. A. Provide up-escalators wherever the vertical distance between floor levels exceeds 3.7m and down- escalators wherever the vertical distance between floor levels exceeds 7.3m. B. Provide elevators where the vertical distance between floor levels exceeds 1.5m; platform lifts as defined in CSA B651 may be used where the vertical distance between floor levels is between 1.5m and 2.5m.
Vertical Circulation o Landlord will replace elevator controls and control panels to meet ADA standards and applicable Legal Requirements. o Landlord will repair and service elevators -- replacing all components which are not functioning, consistent with the existing design and configuration (as opposed to upgrading). Replacement or upgrading of elevator cab finishes will be Tenant's sole responsibility. o Landlord shall make no upgrades or modifications to the Building stairwells, other than life safety and fire safety improvements solely within the stairwells themselves in order to meet applicable Legal Requirements.
Vertical Circulation enlarged floor plans and sections for stairs and elevators. .6 Engineering and Systems Disciplines: Mechanical systems plans; Plumbing systems plans; Electrical systems plans; Structural floor plan(s) and calculations; Acoustic design narrative; Audio/Visual design narrative; Data systems design narrative; Kitchen design plan(s) including equipment layouts and preliminary equipment list(s); Architectural design narrative; Security and Access Control systems narrative and plans.

Related to Vertical Circulation

  • Directory Publication Nothing in this Agreement shall require Verizon to publish a directory where it would not otherwise do so.

  • Project Management Plan Developer is responsible for all quality assurance and quality control activities necessary to manage the Work, including the Utility Adjustment Work. Developer shall undertake all aspects of quality assurance and quality control for the Project and Work in accordance with the approved Project Management Plan and

  • Prospectuses and Marketing Materials We shall furnish you without charge reasonable quantities of offering Prospectuses (including any supplements currently in effect), current shareholder reports of the Funds, and sales materials issued by us from time to time. In the purchase of shares through us, you are entitled to rely only on the information contained in the offering Prospectus(es). You may not publish any advertisement or distribute sales literature or other written material to the public that makes reference to us or any of the Funds (except material that we furnished to you) without our prior written approval.

  • WASHINGTON’S ELECTRONIC BUSINESS SOLUTION (WEBS). Contractor represents and warrants that Contractor is registered in Washington’s Electronic Business Solution (WEBS), Washington’s contract registration system and that, all of Contractor’s information therein is current and accurate and that throughout the term of this Contract, Contractor shall maintain an accurate profile in WEBS.

  • zone Information Publication ICANN’s publication of root-zone contact information for the TLD will include Registry Operator and its administrative and technical contacts. Any request to modify the contact information for the Registry Operator must be made in the format specified from time to time by ICANN at ▇▇▇▇://▇▇▇.▇▇▇▇.▇▇▇/domains/root/.