INDIVIDUAL PROJECT REQUIREMENTS Clause Samples

The 'Individual Project Requirements' clause defines the specific obligations, standards, or deliverables that apply uniquely to a particular project under a broader agreement. It typically outlines tailored expectations such as timelines, technical specifications, or performance criteria that differ from general contract terms. By clearly delineating these project-specific requirements, the clause ensures that both parties understand their precise responsibilities, reducing ambiguity and helping to prevent disputes related to scope or performance.
INDIVIDUAL PROJECT REQUIREMENTS. 3.3.1 Each IPPA shall represent a separate and distinct construction project(“Individual Project”). Attached to each IPPA and made a part of this Agreement is the Design, Construction and Equipment Budget, a component of which is the Individual Project Construction Budget. The Individual Project Construction Budget shall be defined as the total cost of constructing the Individual Project identified in the IPPA. A component of the Individual Project Construction Budget is the Construction Contract Award Price, hereinafter referred to as CCAP. The Engineer shall prepare drawings, specifications and other documents necessary so that the construction contract bid from a responsive, responsible bidding contractor, acceptable to the Owner, will be within the CCAP. 3.3.1.1 During the Design Phase of each Individual Project the Engineer shall prepare such estimates as it deems necessary, at no additional cost to the Owner, to assure itself that the estimated Individual Project cost is within the CCAP and shall supply such data, information or estimates as the Owner may require to substantiate the Engineer's contention that the Individual Project cost is within the CCAP. 3.3.1.2 With each Design Phase submittal of the Engineer to the Owner, the Engineer shall make the following statement in writing: "The drawings, specifications, and other documents submitted herewith, in my/our professional opinion, fulfill the Program of Requirements. Further, in my/our professional opinion, the above mentioned documents submitted herewith have been prepared in accordance with the Engineering Services Agreement." With each Design Phase submittal of the Engineer to the Owner and with his certification of the Final Payment to the contractor, the Engineer shall make the following statement in writing: "No asbestos containing building materials have been specified and to the best of my/our knowledge and belief none have been incorporated into this Project."
INDIVIDUAL PROJECT REQUIREMENTS. 3.3.1 Incorporated herein and made a part of this Agreement by reference as part of the IPPA is the Milestone Schedule for each Individual Project which defines the sequence and timing of the design and construction activities. The Milestone Schedule is the schedule to be adhered to by the Commissioning Authority. No deviation from the Milestone Schedule shall be allowed without written approval for a change in the Milestone Schedule, in the form of a Design Phase Change Order executed by the Owner and Commissioning Authority. Should the Owner determine that the Commissioning Authority is behind schedule, the Commissioning Authority shall expedite and accelerate its efforts, including additional manpower and/or overtime, to maintain the approved design schedule at no additional cost to the Owner. 3.3.2 Incorporated herein and made a part of this Agreement by reference is the most recent version of the Wake County Public School System Design Guidelines (Design Guidelines), or the relevant portions thereof, which establish the technical objectives and parameters for the Project. The Commissioning Authority shall comply with the requirements of the Design Guidelines in performing its services pursuant to this Agreement.

Related to INDIVIDUAL PROJECT REQUIREMENTS

  • Project Requirements 1. Project must conform to regulations under 24 CFR Part 92, commonly known as the HOME Regulations.

  • Equipment Requirements No Equipment is provided to Customer as part of this Service.

  • Developer Operating Requirements The Developer must comply with the Transmission Owner’s operating instructions and requirements including but not limited to Transmission Owner’s Operation Coordination Agreement, as it may change from time to time. The Developer must comply with all applicable NYISO tariffs and procedures, as amended from time to time. Whether or not the Large Generating Facility is eligible for the Transition Period LVRT Standard set forth in Appendix G will be determined by the Commission. The Large Generating Facility will comply with the Transition Period LVRT Standard pending issuance of an order by the Commission determining the appropriate LVRT standard. For purposes of compliance with Appendix G, the Transmission Owner has determined that the Developer shall maintain the Large Generating Facility in service during a three-phase fault for 7 cycles. Infrastructure security of New York State Transmission System equipment and operations and control hardware and software is essential to ensure day-to-day New York State Transmission System reliability and operational security. The Commission will expect the NYISO, all Transmission Owners, all Developers and all other Market Participants to comply with the recommendations offered by the President’s Critical Infrastructure Protection Board and, eventually, best practice recommendations from the electric reliability authority. All public utilities will be expected to meet basic standards for system infrastructure and operational security, including physical, operational, and cyber-security practices. All personnel working in Transmission Owner’s facilities will require security background checks prior to entering and working in such facilities. New York Independent System Operator, Inc. Attn: Vice President, Operations ▇▇▇▇ ▇▇▇▇▇▇ ▇▇▇▇ Schenectady, NY 12303 Senior Vice President of Transmission New York Power Authority ▇▇▇ ▇▇▇▇ ▇▇. ▇▇▇▇▇ ▇▇▇▇▇▇, ▇▇ ▇▇▇▇▇-▇▇▇▇ Re: Large Generating Facility Dear : On [Date] [Developer] has completed Trial Operation of Unit No. . This letter confirms that [Developer] commenced Commercial Operation of Unit No. at the Large Generating Facility, effective as of [Date plus one day]. Thank you. NYISO:

  • Basic Requirements To be eligible for PayPal’s Seller Protection program, all of the following basic requirements must be met, as well as any applicable additional requirements: • The primary address for your PayPal account must be in the United States. • The item must be a physical, tangible good that can be shipped, except for items subject to the Intangible Goods Additional Requirements. Transactions involving items that you deliver in person in connection with payment made in your physical store, may also be eligible for PayPal’s Seller Protection program so long as the buyer paid for the transaction in person by using a PayPal goods and services QR code. • You must ship the item to the shipping address on the Transaction Details page in your PayPal account for the transaction. If you originally ship the item to the recipient’s shipping address on the Transaction Details page but the item is later redirected to a different address, you will not be eligible for PayPal’s Seller Protection program. We therefore recommend not using a shipping service that is arranged by the buyer, so that you will be able to provide valid proof of shipping and delivery. • The shipping requirement does not apply to eligible transactions involving items that you deliver in person; provided, however, that you agree to provide us with alternative evidence of delivery or such additional documentation or information relating to the transaction that we may request. • You must respond to PayPal’s requests for documentation and other information in a timely manner as requested in our email correspondence with you or in our correspondence with you through the Resolution Center. If you do not respond to PayPal’s request for documentation and other information in the time requested, you may not be eligible for PayPal’s Seller Protection program. • If the sale involves pre-ordered or made-to-order goods, you must ship within the timeframe you specified in the listing. Otherwise, it is recommended that you ship all items within 7 days after receipt of payment. • You provide us with valid proof of shipment or delivery. • The payment must be marked “eligible” or “partially eligible” in the case of Unauthorized Transaction claims, or “eligible” in the case of Item Not Received claims, for PayPal’s Seller Protection program on the Transaction Details page. • In the case of an Unauthorized Transaction claim, you must provide valid proof of shipment or proof of delivery that demonstrates that the item was shipped or provided to the buyer no later than two days after PayPal notified you of the dispute or reversal. For example, if PayPal notifies you of an Unauthorized Transaction claim on September 1, the valid proof of shipment must indicate that the item was shipped to the buyer no later than September 3 to be eligible for PayPal’s Seller Protection program. PayPal determines, in its sole discretion, whether your claim is eligible for PayPal’s Seller Protection program. PayPal will make a decision, in its sole discretion, based on the eligibility requirements, any information or documentation provided during the resolution process, or any other information PayPal deems relevant and appropriate under the circumstances. To be eligible for PayPal’s Seller Protection program for a buyer’s Item Not Received claim, you must meet both the basic requirements and the additional requirements listed below: • Where a buyer files a chargeback with the issuer for a card-funded transaction, the payment must be marked “eligible” for PayPal’s Seller Protection on the Transaction Details page. • You must provide proof of delivery as described below.

  • Agreement Requirements This agreement will be issued to cover the Janitorial Service requirements for all State Agencies and shall be accessible to any School District, Political Subdivision, or Volunteer Fire Company.