Substructure Foundation Alternatives Sample Clauses

Substructure Foundation Alternatives. The Consultant shall evaluate at a minimum two separate substructure types for possible development during final design. Whenever soil conditions allow, a shallow and a deep alternative shall be evaluated. Each substructure type shall be developed to the point of pile and/or footing size selection and spacing to allow for constructability and cost analysis to be performed.

Related to Substructure Foundation Alternatives

  • Framework Management Structure The Supplier shall provide a suitably qualified nominated contact (the “Supplier Framework Manager”) who will take overall responsibility for delivering the Goods and/or Services required within this Framework Agreement, as well as a suitably qualified deputy to act in their absence. The Supplier shall put in place a structure to manage the Framework in accordance with Framework Schedule 2 (Goods and/or Services and Key Performance Indicators). A full governance structure for the Framework will be agreed between the Parties during the Framework Agreement implementation stage. Following discussions between the Parties following the Framework Commencement Date, the Authority shall produce and issue to the Supplier a draft Supplier Action Plan. The Supplier shall not unreasonably withhold its agreement to the draft Supplier Action Plan. The Supplier Action Plan shall, unless the Authority otherwise Approves, be agreed between the Parties and come into effect within two weeks from receipt by the Supplier of the draft Supplier Action Plan. The Supplier Action Plan shall be maintained and updated on an ongoing basis by the Authority. Any changes to the Supplier Action Plan shall be notified by the Authority to the Supplier. The Supplier shall not unreasonably withhold its agreement to any changes to the Supplier Action Plan. Any such changes shall, unless the Authority otherwise Approves, be agreed between the Parties and come into effect within two weeks from receipt by the Supplier of the Authority’s notification. Regular performance review meetings will take place at the Authority’s premises throughout the Framework Period and thereafter until the Framework Expiry Date (“Supplier Review Meetings”). The exact timings and frequencies of such Supplier Review Meetings will be determined by the Authority following the conclusion of the Framework Agreement. It is anticipated that the frequency of the Supplier Review Meetings will be once every month or less. The Parties shall be flexible about the timings of these meetings. The purpose of the Supplier Review Meetings will be to review the Supplier’s performance under this Framework Agreement and, where applicable, the Supplier’s adherence to the Supplier Action Plan. The agenda for each Supplier Review Meeting shall be set by the Authority and communicated to the Supplier in advance of that meeting. The Supplier Review Meetings shall be attended, as a minimum, by the Authority Representative(s) and the Supplier Framework Manager.

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Management Structure Describe the overall management approach toward planning and implementing the contract. Include an organization chart for the management of the contract, if awarded.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If WCS chooses to subtend a Verizon access Tandem, WCS’s NPA/NXX must be assigned by WCS to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 WCS shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from WCS’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office WCS utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow WCS’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • Please see the current Washtenaw Community College catalog for up-to-date program requirements Conditions & Requirements