Ceiling System Sample Clauses

Ceiling System. Ceiling systems must conform to fire, acoustics, maintenance and light reflection requirements. Gypsum board ceiling suspension systems shall have 16 gauge, 1 – ½” main channels with 25 gauge 7/8” furring channels. Acoustic panel ceilings shall comply with ASTM E1374 classifications and metal suspension systems with applicable ASTM C635 requirements. Suspend lighting fixtures independent of ceiling. Provide edge moldings, trim and acoustical sealant as required. Exposed face shall be white enamel. Grid spacing shall be 24” x 48”.
Ceiling System. The Landlord will provide a suspended T-Bar ceiling system with 2' x 4' lay-in acoustical tile for tenant ceiling on a "single plane basis". Ceiling height to be 10 feet. Any additional cost of installing the ceiling system caused by partition walls or other interior Tenant improvements shall be borne by Tenant.
Ceiling System. The installation of a 2 ft. x 2 ft. modular ceiling grid system similar to a ▇▇▇▇ Fine-line. Tenant may remove the ceiling grid system.
Ceiling System. Tenant requires the Building’s ceiling finish height to be a minimum of nine (9) feet, and the Landlord to install a drop, T-bar ceiling system, with new ceiling tile (▇▇▇▇▇▇▇▇▇ Cirrus or equivalent) stockpiled in the floor for installation by Tenant.
Ceiling System. Tenant's ceiling construction (in excess of that supplied by Landlord per paragraph 3 above) and installation of acoustical ceiling tile.
Ceiling System a. Ceiling Tile:
Ceiling System. USG DX26 heavy duty grid with 2 x 2 Tegular USG Eclipse #76775 or equal (or match existing). Install in accordance with U.B.C. STD. NO. 47-18. Carpet and Title (Floor Coverings): ----------------------------------- See Exhibit 2-B (Tenant Specifications) Window Coverings - Exterior Windowline: --------------------------------------- Off-white Louverdrape verticals (with p-21) 3-1/2" vanes, or equal. Window Coverings - Interior Windows: ------------------------------------ See Exhibit 2-B (Tenant Specifications). Paint and Finishes: ------------------- See Exhibit 2-B (Tenant Specifications).
Ceiling System 

Related to Ceiling System

  • Ceilings 13.1 Lambdaboard ceilings, minimum 25mm thick with a width of 1220mm x 1800mm, skimmed with Plascon EZ Joint and EZ Skim system. 13.2 Cornices to be Nucornice polystyrene core cove cornice as per Everite or similar approved. ▇▇▇▇ Shadow line cornices will be at extra cost if required.

  • Ceiling Company and its subcontractors will not affix, attach, or suspend any lighting fixtures, signs, or other fixtures or devices of any kind or nature from the ceiling above any of the Premises without the prior written approval of Authority.

  • Filing Systems and Equipment A complete and comprehensive catalog of filing systems including vertical and lateral files, bookcases, mobile cabinets and freestanding file cabinets.

  • Building Systems “Building Systems” shall mean all structural elements and components, mechanical equipment, plumbing systems, electrical systems and life safety systems and fixtures incorporated in the Improvements, including, without limitation, HVAC, elevator, electrical, plumbing, utility, fire and life safety and swimming pool.

  • Walls 12 Developer shall provide rustication patterns on all walls, except drainage headwalls, in Aesthetic 13 Area 3 in accordance with Exhibit L2.24 of the LAADCR. The final designs shall resemble these 14 simulations.