Post-Accident Testing a. The City may require a Covered Employee who caused, or may have caused, an Accident, based on information known at the time of the Accident, to submit to drug and/or alcohol testing. b. Following an Accident, all Covered Employees subject to testing shall remain readily available for testing. A Covered Employee may be deemed to have refused to submit to substance abuse testing if the employee fails to remain readily available, including failing to notify a supervisor (or designee) of the Accident location, or leaving the scene of the Accident prior to submitting to testing. c. Nothing in this section shall delay medical attention for the injured following an Accident or prohibit an employee from leaving the scene of an Accident for the period necessary to obtain assistance in responding to the Accident or to obtain necessary emergency medical care. d. If the City requires a Covered Employee to be tested post-Accident, then the employee may ask for representation. Representation may include, but is not limited to, union representatives and shop stewards. If the employee requests representation, the City shall allow a reasonable amount of time from the time the employee is notified that the employee will be tested (a maximum of one hour) for the employee to obtain representation provided that the union representative meet the employee at the Accident site, work location or testing center as determined by the City. Such request shall not delay the administration of the tests for more than one hour from the time the employee is notified that the employee will be tested. e. As soon as reasonably possible after the occurrence of an Accident, the supervisor or other City representative at the Accident scene shall make best efforts to contact the Department of Human Resources (DHR) or designee, and DHR or designee shall then make best efforts to telephone the union(s) first designated representative on file with DHR representing the Covered Employee(s) involved in the Accident. If the first designated representative does not answer, DHR or designee shall leave a voice mail message notifying the union of the Accident and telephone the union(s) second designated representative on file with DHR. For purposes of this paragraph, a designated representative shall be any union officer or employee whose telephone number is on file with DHR for the purpose of Accident review. The union may change the designated representative, in writing, as necessary from time to time, but it is the sole responsibility of the union to ensure that a current telephone number (with voice mail capability) for two designated representatives are on file with DHR.
Follow-up Testing An employee shall submit to unscheduled follow-up drug and/or alcohol testing if, within the previous 24-month period, the employee voluntarily disclosed drug or alcohol problems, entered into or completed a rehabilitation program for drug or alcohol abuse, failed or refused a preappointment drug test, or was disciplined for violating the provisions of this Agreement and Employer work rules. The Employer may require an employee who is subject to follow-up testing to submit to no more than six unscheduled drug or alcohol tests within any 12 month period.
Laboratory Testing All laboratories selected by UPS Freight for analyzing Controlled Substances Testing will be HHS certified.
Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester. 7.2.2 No later than thirty (30) Days prior to the earlier of the Scheduled Substantial Completion Date or Substantial Completion, Design-Builder shall provide to Owner for review a detailed testing plan for the Performance Tests (other than for air emissions). Owner and Design-Builder shall agree upon a testing plan that shall be consistent with the Performance Test Protocol contained in Exhibit A hereto. After such agreement has been reached, Design-Builder shall notify the Owner five (5) business days prior to the date Design-Builder intends to commence the Performance Tests and shall notify the Owner upon commencement of the Performance Tests. Owner and Independent Engineer each have the right to witness all testing, including the Performance Tests and any equipment testing, whether at the Site or at the Subcontractor’s or equipment supplier’s premises during the course of this Agreement. Notwithstanding the foregoing sentence, Owner shall bear the costs of providing a witness to any such testing and all such witnesses shall comply at all times with Design-Builder’s, Subcontractor’s or equipment supplier’s safety and security procedures and other reasonable requirements, and otherwise conduct themselves in a manner that does not interfere with Design-Builder’s, Subcontractor’s or equipment supplier’s activities or operations. 7.2.3 Design-Builder shall provide to Owner a Performance Test report (excluding results from air emissions testing), including all applicable test data, calculations and certificates indicating the results of the Performance Tests and, within five (5) business days of Owner’s receipt of such results, Owner, Independent Engineer and Design-Builder will jointly inspect such Work and review the results of the Performance Tests to verify that the Performance Guarantee Criteria have been met. If Owner or Independent Engineer reasonably determines that the Performance Guarantee Criteria have not been met, Owner shall notify Design-Builder the reasons why Owner determined that the Performance Guarantee Criteria have not been met and Design-Builder shall promptly take such action or perform such additional work as will achieve the Performance Guarantee Criteria and shall issue to the Owner another notice in accordance with Section 7.2.2; provided however that if the notice relates to a retest, the notice may be provided no less than two (2) business days prior to the Performance Tests. Such procedure shall be repeated as necessary until Owner and Independent Engineer verifies that the Performance Guarantee Criteria have been met. 7.2.4 If Owner, for whatever reason, prevents Design-Builder from demonstrating the Performance Guarantee Criteria within thirty (30) Days of Design-Builder’s notice that the Plant is ready for Performance Testing, then Design-Builder shall be excused from demonstrating compliance with the Performance Guarantee Criteria during such period of time that Design-Builder is prevented from demonstrating compliance with the Performance Guarantee Criteria; provided however that Design-Builder will be deemed to have fulfilled all of its obligations to demonstrate that the Plant meets the Performance Guarantee Criteria should such period of time during which Design-Builder is prevented from demonstrating the Performance Criteria exceed thirty (30) Days or extend beyond the Final Completion Date.