Computer Data Centers Server Rooms Sample Clauses

The 'Computer Data Centers Server Rooms' clause defines the requirements and standards for areas within a facility that house computer servers and related equipment. It typically outlines specifications for environmental controls such as temperature, humidity, and power supply, as well as security measures and access restrictions to ensure the safe and reliable operation of critical IT infrastructure. By establishing these guidelines, the clause helps prevent equipment failure, data loss, and unauthorized access, thereby ensuring the continuous and secure functioning of essential technology systems.
Computer Data Centers Server Rooms. If required in the Request for Proposal (RFP), Program, or State Agency Supplementary Standards or the building program, provide required electrical for any Computer Data Centers, Server Rooms or Computer Training Rooms.
Computer Data Centers Server Rooms. If required in the Request for Proposal (RFP), Program, or State Agency Supplementary Standards or the building program, provide special HVAC equipment required for any Computer Data Centers, Server Rooms or Computer Training Rooms. Code Reference HVAC Systems –Michigan Uniform Energy Code, latest edition Michigan Mechanical Code, latest edition Ductwork – SMACNA, latest editionPlumbing ‐‐ Michigan Plumbing Code, latest edition Temperature 73°F ± 4°F (± 5°F for Leases) Humidity 30‐50% Ventilation Office Space: 20 cfm per person or 0.2 cfm / sq. ft. (whichever is greater) Break Room: 30 cfm per person Waiting Area: 15 cfm per person Kitchen/Toilet/Janitor’s Closest: 10 air changes per hour and 100% exhaust Air Conditioning Equipment: 3 ▇▇▇▇▇ / sq. ft. Lighting: 2 ▇▇▇▇▇ / sq. ft. Ductwork Supply and Return air shall be ducted (except at raised floor systems). Return air plenums are not acceptable. Duct insulation shall be external wrap only; no internally lined duct will be accepted. Flex duct allowed within 10‐feet of ceiling diffusers. Miscellaneous Provide a minimum of 1 electric water cooler and drinking fountain combination unit with bottle filler. Locate adjacent to restrooms. ASTM Schedule 40 Chilled water up to 12‐inch diameter. Condenser water up to 12‐inch diameter. 150 psi fittings. Standard weight pipe over 12‐inch diameter. 150% of working pressure Hot water Test to 300 psig. Natural gas Weld and test to 300 psig ASTM schedule 80 Steam over 15 psig Test to 500 psig, 150% of working pressure Copper tubing (no PEX) Chilled water, Condenser water Builder option. Use type K below ground and type L above ground. Domestic water Lead free solder connections Refrigeration Type ACR Cast Iron Sanitary, waste and vent PVC Storm Below grade only
Computer Data Centers Server Rooms. If required in the RFP or the building program, provide special HVAC equipment required for any Computer Data Centers or Server Rooms.

Related to Computer Data Centers Server Rooms

  • Computer Equipment No computers and/or personal electronic devices, such as tablets and laptop computers, or any component thereof, may be purchased with funds provided under this Contract, regardless of purchase price, without prior written approval of ADMINISTRATOR. Any such purchase shall be in accordance with specifications provided by ADMINISTRATOR, be subject to the same inventory control conditions specified above in Subparagraphs 18.1.1 to 18.1.4, and, at the sole discretion of ADMINISTRATOR, become the property of COUNTY upon termination of this Contract.

  • Web Site Information on registration for and use of the E-Verify program can be obtained via the Internet at the Department of Homeland Security Web site: ▇▇▇▇://▇▇▇.▇▇▇.▇▇▇/E-Verify.

  • Server Software Subject to the terms and conditions of this ▇▇▇▇, Vocera grants you the non-exclusive right to (i) install and run (“Use”) the Server Software on computer systems (each, a “Server Computer”) located at End User’s Facilities in the geographic territory designated above (“Territory”); (ii) to Use the Client Software in conjunction with Authorized Client Devices and such Server Computers; and (iii) for pilot licenses for certain Software provided on a trial basis, use such Software for the limited term specified by Vocera in writing. You may Use the standard Server Software on one primary Server Computer (or a primary cluster of computers suitably configured for productive use of the Server Software). You may install backup copies of the Server Software on backup Server Computers to provide redundancy in the event of failure of the primary Server Computer(s) but, unless you have acquired additional licenses or a failover license from Vocera, you may not run such backup or additional copies concurrently with the primary copies. Vocera grants you the right to use the applicable License Key issued by Vocera only to enable Use of the Server Software in conjunction with the licensed Server Computers. Server Software may be licensed for a Subscription Term as specified in the Quote.

  • Computer Systems (a) Servicer to operate systems (b) Servicer to maintain back-up facilities (c) Servicer to notify location of computer tapes

  • Computer Software The Grantee certifies that it has appropriate systems and controls in place to ensure that state funds will not be used in the performance of this Grant Agreement for the acquisition, operation, or maintenance of computer software in violation of copyright laws.