Building Setbacks Sample Clauses

Building Setbacks. Building setbacks from all roads shall not be less than 80 feet from the road right of way.
Building Setbacks. The setback from the porch or front plane of the dwelling is a minimum thirty (30) foot from the front Lot Line. Together, the two side yards must be a minimum of thirty (30) feet with a minimum of ten (10) feet on one side. On a case-­‐by-­‐case basis a variance from the ACC may be given to decrease the minimum to twenty (20) feet total for the two side yards together. The minimum distance from the back Lot line to the Dwelling must be thirty (30) feet. On a case-­‐by-­‐case hardship basis a variance from the ACC may allow the distance from the back Lot line to the Dwelling to be decreased to twenty (20) feet. The minimum setback from the porch or front plane of a Dwelling built on a corner Lot must be thirty (30) feet in the front yard and twenty (20) feet on the corner side.
Building Setbacks. Setback requirements shall be based upon the site plan as approved by City Council.
Building Setbacks. (a) Buildings shall have minimum set backs from boundaries as follows: i. Any boundary adjoining the railway designation (Designation F1) ii. Transport corridor boundary – local and collector transport corridors iii. Transport corridor boundary – arterial transport corridors
Building Setbacks. 3.2.1 Building Setbacks for the Site Development Plan are detailed on Map 5 (Site Development Plan) of this document. These Building Setbacks demonstrate the following: • Buildings along Lake Kawana Bvd have minimum 3m setbacks. These setbacks provide a solid built form to reinforce the street edge. Awnings to all buildings on these allotments are permitted to encroach within the footpath setback and footpath of the public road, subject to approval from Council and should not impact on street tree planting. • Building elements (entry canopies, covered walkways, pergolas, screens, horizontal, vertical and oblique, shade devices, minor ▇▇▇▇▇▇ levered building elements, planter units, seating, sculptural elements, horticultural elements or the like) which provide a transition in terms of bulk and scale between the pedestrian streetscape and the building frontage are encouraged within the nominated transition zone setback 0-3m from the front property boundary. The building elements should define points of entry and create an identity in terms of building design and appearance. • Zero setbacks are permitted (but not required) except as referred to above, for all buildings and building elements subject to approval from Council to allow greater flexibility in the architectural design of buildings. These setbacks should define possible plaza / pedestrian areas and/or create interest in the built form recognising it forms part of a key vista. Any application to reduce the building setbacks on the northern boundary with the Community Use Park below the required 3 m stipulated setback requirement to the walkable waterfront will be determined by Council, based on its merits, as part of a subsequent Material Change of Use application. Any application to reduce the building setbacks on the northern boundary of lot 2 below the required 3 m stipulated setback requirement to the walkable waterfront, will be determined by Council, based on its merits, as part of a subsequent Material Change of Use application. • The building setbacks for the Column 1 use, Commercial Premises – Sales and Information Centre, as specified in this section, may be varied in that: a) the building need not directly address the street frontage; b) the setback transitional zone abutting the Public Access Promenade may be reduced to
Building Setbacks. (a) Subject to the provisions of Section 6.05 below, the minimum building setback lines for all lots shall be 35 feet from the front property line and 15 feet from the back and side property lines; except that a 5 foot minimum side or back setback shall be permitted for a garage or other permitted accessory building. There shall be no clearing of any kind or building of any structure as to encroach or disturb the designated Buffer Zones on lots along Creekside Cove Road and as discussed in Section 3.05 of these Covenants. (b) No dwelling or Improvement shall be built within the setback areas established in Section 6.04(a), unless the Owner obtains a variance from the Developer or the ARC or any Governmental Authority having jurisdiction thereof, if necessary. All ▇▇▇▇▇, steps, porches, terraces, decks, and patios shall be deemed a part of the dwelling for the purposes of determining building setback areas pursuant to this Section 6.04.
Building Setbacks. None, but the building location must be approved by the Planning Director.
Building Setbacks. Unless otherwise provided, buildings and other structures shall be set back a distance of 15 feet from the edges of all critical area buffers or from the edges of all critical areas if no buffers are required. The following may be allowed in the building setback area: landscaping; uncovered decks; building overhangs, if such overhangs do not extend more than 18 inches into the setback area; and impervious ground surfaces, such as driveways and patios.
Building Setbacks. All structures, excluding well houses not exceeding 3' X 3', must have at least a 45' or more front setback (corner lots are considered to have double frontage regardless of drive access), 20' side and 25' rear setbacks.
Building Setbacks. Building setbacks shall be a minimum of 85 feet from the north, south and west Project boundaries, except for garage buildings, which may follow a 10 foot building setback. Building setbacks from the eastern boundary of the Project shall be a minimum of 50 feet, consistent with the pattern of existing site development.