VDC Sample Clauses

VDC. Maximum is 2.35
VDC. Pilot cell is lowest per cell voltage of the 24 cells. If below minimum, equalize batteries for 12-24 hours. If above 2.27 VDC, decrease charger float voltage.
VDC. Minimum is 2.20
VDC. Intermittent mode switch results in the pump operating 5 minutes on and 2 minutes off, with intermittent LED on at all times. Pressing intermittent switch during operation stops intermittent mode.
VDC. The system was designed to sense voltage on the battery and automatically selects one of 3 operating modes (normal, boost and storage) to provide the correct charge level to the batteries. NOTE: Your Inteli-Power 9200 Converter/Charger may have been supplied with a Remote Pendant. The Remote Pendant is optional on OEM but is included with all retail models and plugs in to the accessory port of the 9200 Converter/Charger. While the built-in Charge Wizard automatically determines which operating mode is best suited to recharge or maintain optimum battery condition, the Remote Pendant allows for manual override and has an indicator light(s) to indicate the mode of operation. BOOST MODE – Indicated by green LED remaining on. The output voltage is 14.4VDC to rapidly recharge the battery up to 90% of full charge.
VDC. The -48VDC Battery Plant shall have the positive terminal grounded. The rated battery capacity in ampere-hours shall be sufficient to supply the entire DC load for four hours at 25° C (77° F) The rated battery capacity shall be met under the following conditions: • Temperature = 25°C (77° F) • Four (4) Hour discharge time The Input/Output terminals on the battery plant shall be large lead-coated copper plates with adequate holes in each terminal for the following as a minimum: • Negative: Two 9/16” hole sets on 1-3/4” centers (T&B), one 9/32” hole set on 5/8” centers (T&B) • Positive: Two 9/16” hole sets on 1-3/4” centers (T&B), one 9/32” hole set on 5/8” centers (T&B)
VDC. Video Configuration screen By pressing the Video and Bright simultaneously and holding them for three seconds. The Video Configuration screen will appear. There are several items on this screen, which you can scroll through using the Knob. Saturation This selection allows a value in the range of 0 to 255. Adjust to taste. Hue This selection allows a value in the range of 0 to 255. Adjust to taste. Configuration This selection is for future options, and will always be set at ▇▇▇▇- dard. Reset To Defaults This selection resets the current video screen selected to the fac- tory defaults. Go to Video 1,2,3, or 4 This selection switches between the Video Inputs. Ask Us About Available Accessories To Compliment Your VMS System Tire Pressure Monitoring: Tire pressure monitoring gives internal pressure and temperature readings of each tire while driving down the road right on your VMS screen. It acts as an early warning system in the event of loss of tire pressure, or extreme rise in temperature for coach and towed vehicles. Supported Systems: Advantage PressurePro is available at the time of install or down the road. We also support legacy systems such as SmarTire and Valor--though not all features of each legacy system may be accessible. Table of Contents Quick Start Guide 2 Drive Screens 4 Scan Screen 5 Trip Screens 7 Diagnostics Screens 8 Information Screens 9 Programming Screens 12 Scan Preference Screens 14 Special Screens 15 Hidden Screens 16 Accessories List. 18 Warranty 20
VDC. Adjust each rectifier to within .1 VDC of each other. o Verify equalize voltage is -55.2 VDC to -56.4 VDC for each rectifier. Adjust each rectifier to within .1 VDC of each other. Verify at battery plant. o Verify current limit setting and operation of each rectifier. o Verify operation of forced paralleling. Adjust as required. o Verify operation and accuracy of DC volts and amps output monitor meters. Adjust meter monitor calibration as required.
VDC. The minimum connection to a vehicle is three wires to gain Battery, Ignition and Ground connectivity with the fitment of two antennas allowing GPS positioning and cellular communication. We use environmentally sound practices to ensure the protection of our surrounding environment. Environmental regulations may include rules governing the use, control, transportation, storage and disposal of regulated materials that may reach the environment as a part of wastewater, air emissions, solid waste, hazardous waste or uncontained spills. Even non-regulated materials must be managed in a responsible, sustainable manner. Many of these non-regulated materials can also have adverse environmental impacts if mishandled. As part of the Vontier Group of companies, we are committed to: • continuous improvement in environmental performance, waste minimization and prevention of pollution • integration of sound environmental practices into applicable business functions, including procurement and product design, testing, manufacturing and support • consideration of environmental impacts while developing new products or processes, in selecting production materials, and before buying, leasing or selling property • design, operation and maintenance of our facilities in a manner that minimizes emissions and waste • responsible use of materials, including, where feasible, the recycling and reuse of materials We operate responsibly in all we do to minimize our impact on the environment. Our products are designed to help organizations with fleet vehicles reduce their environmental footprint by delivering more fuel-efficient fleets. 45 Identify any third-party issued eco- labels, ratings or certifications that your company has received for the Solutions included in your Proposal related to energy efficiency or conservation, life-cycle design (cradle-to-cradle), or other green/sustainability factors. Gilbarco's e-mobility hardware partners bring significant value through their prestigious certifications, ensuring both efficiency and compliance with industry standards. Gilbarco's e-mobility hardware supplier, Kempower, has been awarded ISO certification ISO14001:2015. By adopting this standard Kempower has enhanced their environmental performance, regulatory compliance and has engaged continuous improvement processes to streamline operations, minimize waste and enhance productivity. Kempower has performed LCA (Life Cycle Assessments) in accordance with ISO 14040 and 14044 to determine...