Telephone and Data. Equipment Location: Tenant shall advise Landlord of location of telephone equipment room, if any.
Telephone and Data. The building shell will provide conduit from the street to the base building’s demarcation point. Telephone closets are located for tenant distribution requirements. SCHEDULE 2 MINIMUM STANDARD TENANT IMPROVEMENTS BUILDING STANDARD SPECIFICATIONS TENANT AREA: COMMON CORRIDOR PARTITION: • • • • • Full height partition, floor to underside of structure, by landlord and tenant. 3 5/8”, 25 gauge metal studs, 16” OC 5/8” type-X drywall, one layer each side, landlord to provide finished partition at common corridor. Tenant to provide finished drywall at suite interior. Cost shared by landlord and tenant, 50% each. Partition taped smooth and sanded to receive paint or wallcovering Partition cavity fully insulated DEMISING PARTITION: • • • • • Full height partition, floor to underside of structure, by tenant 3 5/8”, 25 gauge metal studs, 16” OC 5/8” type-X drywall, one layer each side (1 hr. Fire rated) Partition taped smooth and sanded to receive paint or wallcovering Partition cavity fully insulated INTERIOR PARTITION: • • • • 9’-6” high partition, floor to 6” above ceiling, by tenant 3 5/8”, 25 gauge metal studs, 16” OC 5/8” type-X drywall, one layer each side Partition taped smooth and sanded to receive paint or wallcovering PERIMETER WALLS: • 5/8” type-X drywall, one layer, installed below window and at bulkhead above window. Provide “L” bracket to seal opening between glazing and floor, by tenant BUILDING STANDARD SPECIFICATIONS TENANT AREA: • • • Shell includes metal studs and insulation, tenant responsible for enclosing perimeter, typ. Windowsill to be anodized aluminum, color: Champagne, included in building shell. Sill height (where ▇▇▇▇▇ exist): 2’-10” AFF; underside of window head: 8’-10” AFF (VIF) ▇▇▇▇▇ are not to be modified, cut or removed, typ. INTERIOR COLUMNS: • 5/8” type-X drywall, one layer over 2 V” metal stud or furring strips, floor to 6” above ceiling as required to enclose column, by tenant. CORRIDOR DOOR: • • • • • • 3’-0” x 8’-0” flush, solid core wood, Mohawk Flush Doors, Inc., prefinished premium 2000, to match Building Standard Hollow metal knock-down frame, 2” face, 16 gauge cold-rolled steel, factory primed to receive paint Falcon “Quantum” series entry lockset #B501, lever handle ▇▇▇▇▇ (or equal) 4 1⁄4 x 4 1⁄2 hinges, #BB 1168, stainless steel ball bearing, 2) pair Door equipped with Closer: Dor-o-matic or equal, Silencer: Ives or equal, Wall or Floor Stop: Rockwood Manufacturing or equal All hardware to match brushed chrome, US26D ...
Telephone and Data. (i) Landlord shall maintain, repair and replace a telecommunications infrastructure (such infrastructure, together with any riser space that Tenant may use pursuant to Article 26 below, is referred to herein as “Landlord’s Telecommunication Infrastructure“), and Tenant shall be permitted to utilize portions thereof, all as more specifically set forth in Exhibit N attached hereto. Landlord agrees that the Landlord’s Telecommunications Infrastructure shall be sufficiently large, and shall contain equipment having sufficient capacity, to accommodate the Lines and telecommunications equipment of Tenant and the telecommunications equipment of the other tenants and occupants of the Building entitled to use the same, and to accommodate reasonable expansions of such uses in connection with reasonably foreseeable changes in technology. All of Landlord’s equipment located in Landlord’s Telecommunications Infrastructure shall be state-of-the-art as of the Effective Date, and Tenant shall have the right to require that Landlord thereafter cause such equipment to be updated to reflect changes in technology in a manner consistent with comparable Class A office buildings in downtown Chicago (in which event any capital expenditures incurred by Landlord in connection therewith shall be included in Operating Expenses in accordance with the same terms as otherwise set forth in clause (42) of Paragraph 3(B)(iii) hereof, amortized as set forth in said clause (42)).
(ii) The installation, maintenance, repair and replacement of any such Lines (and the conduit sleeves, which shall be installed by Landlord at Landlord’s sole cost and expense, for the same) in the Building Riser Closets and the NetPOP Rooms (as each such term is defined in Exhibit N) (herein, the “Riser Closets“ and the “NetPOP Rooms“, respectively) shall be performed by contractors selected by Tenant and approved in advance by Landlord, such approval not to be unreasonably withheld, and, at Landlord’s election, under the supervision of Landlord’s riser manager. Landlord shall not impose any separate charges on Tenant for any use of the Landlord’s Telecommunications Infrastructure by Tenant pursuant to this Lease (including this Article 6, Article 26, Article 27 and/or Article 37 hereof), except for costs relating thereto that are permitted to be included in Operating Expenses pursuant to Article 3 hereof. All installation, maintenance, repair and replacement work performed by Tenant under this Paragraph 6(H) shall...
Telephone and Data. (a) Tenant will construct telephone and data rooms within or adjacent to the building core as part of its tenant improvement package.
(b) Landlord shall provide one dedicated 750 square foot main point of presence (MPOP) room for Tenant's telephone and data service entry into the building. This room shall be used exclusively by Tenant.
(c) Landlord shall also construct one dedicated alternate point of presence (APOP) room for alternate telephone and data service entry into the building.
(d) Landlord shall provide one non-exclusive 500 square foot fiber optic hub room for telephone and data service into the building. The MPOP, APOP and fiber rooms are not alternates, all will be required.
(e) Landlord shall provide dedicated empty conduits from the outside of the building near available services to Tenant's MPOP, APOP and fiber hub rooms. Secure empty conduits must be provided from the MPOP and APOP to each of the Tenant telephone and data rooms within its space and to its expansion space. Landlord must provide such conduits to serve two locations on each floor of the building occupied by Tenant and conduits must be provided between each of the two locations.
(f) Landlord shall provide an adequately sized empty conduit between the MPOP and the APOP.
Telephone and Data. Four (4) 4” conduits shall be provided from utility source to the main telephone/telecommunications room for use by the Tenant’s telephone and data provider. A 4’x8’ sheet of plywood shall be secured to the framing of the main telephone/telecommunications room to accommodate equipment, cabling and hardware. Two (2) 4” riser sleeves (one each for tenant and landlord) shall be provided at each floor to allow connectivity between floors. Two (2) 4” spare conduits shall be provided from the main telephone/telecommunications room to a location outside the building to allow for connectivity with future buildings within the development. General power receptacles will be provided in all core areas as required by code. A complete code compliant fire alarm system shall be installed to accommodate the entire building (including future Tenant Improvements). Only devices (horns, strobes, pull stations, duct smoke detectors, etc.) for the building’s core and shell shall be provided. All devices for the tenant areas shall be designed, furnished, installed and funded through the tenant improvement work. The fire alarm enunciator panel will include a graphic zone plan. Duke Realty Limited Partnership Attention: ______________________, Property Manager RE: Office Lease between Duke Realty Limited Partnership, an Indiana limited partnership doing business in North Carolina as Duke Realty of Indiana Limited Partnership ("Landlord") and ChannelAdvisor Corporation, a Delaware corporation ("Tenant") for the Leased Premises located at ▇▇▇▇ ▇▇▇▇▇▇▇▇▇▇ ▇▇▇▇ Boulevard, Suites 100, 300, 400 and 500, ▇▇▇▇▇▇▇▇▇▇▇, ▇▇▇▇▇ ▇▇▇▇▇▇▇▇ ▇▇▇▇▇ (the "Leased Premises"), within Perimeter Park, dated ________________ (the "Lease"). Dear _________________________: The undersigned, on behalf of Tenant, certifies to Landlord as follows:
Telephone and Data. County shall provide at its cost installation of all telephone and data lines (including Wi-Fi) serving the Premises. Notwithstanding the foregoing, Tenant shall pay, from the Operating Expense Account, the cost to install any additional telephone or data lines or Wi- Fi it may require beyond those in place on the Community Space as of the date hereof, and Tenant shall be responsible for payment for any such additional telephone lines or data services it may require in the Helpline Space. Such installation shall be subject to County's advance written consent. All costs related to use of any telephone and data lines or Wi-Fi serving the Premises during the term hereof (including any extension or holdover) shall be paid from the Operating Expense Account, except that any telephone or data lines or Wi-Fi serving the Helpline Space shall be separately billed and Tenant shall be solely responsible for paying for all outbound calls from telephone lines serving the Helpline Space. In no event shall Tenant be entitled to access the Main Communications Room ("MCR") without County's prior written consent.
Telephone and Data. In new gypsum drywall partitions only, Landlord will provide raceways for the Tenant supplied and installed telephone telephone and data systems. Raceways may be through the metal studs of the gypsum drywall partitions, or in conduit(s) as required, with junction boxes and/or plaster rings. 1. Tenant is responsible for entire telephone system, other than that which is defined under Base Building, including distribution from the existing telephone closet on the ground floor, and for all of the Tenant’s central and branch equipment, distribution panels, wiring, instruments, etc.
Telephone and Data. Two (2) 4” conduit with pull strings shall be provided from each electrical room to property line for telephone and data service. Power shall be provided to all fire protection, H.V.A.C. equipment and all other required building components as outlined in this Building Description. A fire alarm system shall be provided for monitoring of building fire protection system. Design and construction of approximately 5,000 square feet of office and breakroom space. Notwithstanding anything set forth in the Project Specifications and/or the Plans and Specifications to the contrary, the above referenced items shall constitute Tenant Finish Work and shall not be included in the definition of Landlord’s Work under the Lease. This Tenant Work Letter shall set forth the terms and conditions relating to the construction of the Tenant Finish Work in the Building. Capitalized terms used in the Work Letter and not otherwise defined herein shall have the meaning set forth in the foregoing Lease. The improvements to be initially installed in the Building shall be designed and constructed by Tenant pursuant to this Tenant Work Letter.
Telephone and Data. (a) Tenant will construct telephone and data rooms within or adjacent to the building core as part of its tenant improvement package.
(b) Landlord shall provide dedicated space within the main point of presence (MPOP) room for Tenant's telephone and data service entry into the building.
(c) Landlord shall provided dedicated empty conduits from the outside of the building near available services to the Base Building MPOP
(d) The extension of the ▇▇▇▇▇ ▇▇▇▇▇▇▇ Companies communication riser from the 13th floor south communication room through the 14th floor mechanical room can be accommodated at Tenant's expense.