Test System Sample Clauses

Test System. 7.1 If applicable Philips will provide software for an off-line test system after first time commercial purchase of licenses and associated hardware. The Test System is not to be used in a production environment or with patients.
Test System. 12.1 Philips will provide software versions for an off-line test system (“Test System”). The Test System is not to be used in a production environment or to provide patient care. No additional services will be provided hereunder for the Test System. Initial capital purchase of Test System licenses and hardware is Customer’s responsibility. 12.2 Customer shall be entitled to one (1) virtual off-line test system (“Virtual Test System”). The Virtual Test System is not to be used in a production environment or to provide patient care. Software and all future versions will only be installed by Philips during an ongoing upgrade project for PIC iX. Requests by Customer outside an ongoing upgrade project for PIC iX shall be at an additional cost, subject to resource availability.
Test System. 1Philips will provide software versions for an off-line test system (“Test System”). The Test System software version will provide full functionality for up to each PIIC iX patient sector covered under this Agreement. The Test System is not to be used in a production environment or to provide patient care. No additional services will be provided hereunder for the Test System.
Test System. 1. During the course of any executed CTO, Systems tests and inspections shall be made both during the progress of this Contract and after completing installation or modification of equipment, and shall consist of circuit breakdown tests, wiring verification tests, continuity tests, resistance tests, voltage and current tests, applicable locking tests, operating tests, simulation tests, and other electrical and mechanical tests and inspections. 2. The work shall include all tests required to ensure proper and safe operation of all systems and subsystems, and to prove the adequacy and acceptability of the total installation specified herein. Tests to be performed shall cause each system and subsystem to be sequenced through its required operations, including imposition of simulated conditions to prove that the installation complies with all specified fail-safe requirements. 3. The Contractor shall conduct an acceptance test on all Authority furnished equipment prior to loading at the warehouse and provide certified acceptance reports with each unit at time of delivery. 4. The Contractor shall supply test equipment of proper type, capacity, range, and accuracy to perform required tests and inspections. 5. The Contractor’s test equipment used shall be in good working order and properly calibrated within 6 months of the date of the tests. This equipment shall display a sticker indicating its calibration date and the agency/vendor that performed the calibration. a. Calibration of each instrument shall be certified by a recognized testing facility. Instruments with out-of-date calibrations will be considered non-certified. Tests conducted with non-certified instruments will be rejected. 6. In the event that the system does not meet requirements, the Contractor shall make the necessary corrections and perform retesting at the sole expense of the Contractor. The Contractor shall complete all tests and inspections prior to performing final in-service tests. 7. Work shall include all necessary disconnecting and reconnecting in order to perform the specified tests. 8. Systems test work specified elsewhere in this Contract shall be construed as related to and inclusive with the testing described herein. 9. Field tests shall be coordinated with the Authority’s PTC & Systems Engineer or designate. As many tests and inspections as possible shall be completed prior to the final cutover to avoid train delay, inconvenience to the traveling public, and cost to the Authority. ...
Test System. The term “Test System” shall mean the preliminary version of software loaded into the test server environment and progressively configured to be used in training, validation and verification of data and functionality prior to being deployed to production. This may be used in the future to stage updates for testing before production deployment.
Test System. ‌ The intended modularity of micro-ROS, apart from helping with deployment configurations, it dramatically helps to the testability of the whole system. micro-ROS should provide test per each component. Components interfaces are tested to verify the correctness of the functionality provided by it. Unit tests are recommended but not mandatory. The micro-ROS packages also have a test so that the users can verify the correctness of the package interfaces.
Test System. The test system (Figure 8) can apply forces Force between 30 N to about 1800 N with an uncertainty U95% = 10-4. The system is fitted with a laser interferometric system to give high accuracy measurement of the indenter into the sample. The accuracy of the displacement measurement is 0.01 µm. The system can accommodate different types of indenter. In the work carried out in these experiments diamond ▇▇▇▇▇▇▇ indenters were used. The indentation modulus is calculated on the basis of ▇▇▇▇▇▇▇-▇▇▇ linear model and from accurate measurements of indentation load, displacement, contact stiffness and ▇▇▇▇▇▇▇ hardness impression imaging. When an indentation test is carried out, the applied force and indentation depth are measured simultaneously and the resulting load displacement indentation curve is obtained.

Related to Test System

  • Monitoring System In each case in which the Custodian has exercised delegated authority to place Assets with a Foreign Custodian, the Custodian shall establish a system, to re-assess or re-evaluate selected Foreign Custodians, at least annually in accordance with Rule 17f-5(c)(3).

  • Evaluation Software If the Software is an evaluation version or is provided to You for evaluation purposes, then, unless otherwise approved in writing by an authorized representative of Licensor, Your license to use the Software is limited solely for internal evaluation purposes in non-production use and in accordance with the terms of the evaluation offering under which You received the Software, and expires 90 days from installation (or such other period as may be indicated within the Software). Upon expiration of the evaluation period, You must discontinue use of the Software, return to an original state any actions performed by the Software, and delete the Software entirely from Your system and You may not download the Software again unless approved in writing by an authorized representative of Licensor. The Software may contain an automatic disabling mechanism that prevents its use after a certain period of time. RESTRICTIONS

  • CONTROL SYSTEM (a) SELLER shall provide and maintain a quality control system to an industry recognized Quality Standard and in compliance with any other specific quality requirements identified in this Contract. (b) Records of all quality control inspection work by SELLER shall be kept complete and available to LOCKHEED ▇▇▇▇▇▇ and its customers.

  • Hardware and Software Requirements In order to access and retain Disclosures electronically, you must satisfy the following computer hardware and software requirements: access to the Internet; an email account and related software capable of receiving email through the Internet; a web browser which is SSL-compliant and supports secure sessions, and hardware capable of running this software.

  • System Logging The system must maintain an automated audit trail which can 20 identify the user or system process which initiates a request for PHI COUNTY discloses to 21 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY, 22 or which alters such PHI. The audit trail must be date and time stamped, must log both successful and 23 failed accesses, must be read only, and must be restricted to authorized users. If such PHI is stored in a 24 database, database logging functionality must be enabled. Audit trail data must be archived for at least 3 25 years after occurrence.